Assessing the Threshold of Need for Supplemental Damping in Seismic Base Isolation of Multistory Buildings

The comprehension of the threshold for the need of supplemental dampers in the base isolation of multistory buildings could be beneficial in the advancement of the application of base isolation to achieve seismic safety. In this study, stick models of 1‐, 4‐, 7‐, 10‐, 13‐, 16‐, and 19‐story buildings were designed in fixed‐base, simply base‐isolated, and damping‐assisted base‐isolated scenarios. The isolation system considered is the well‐known friction pendulum system, with supplemental damping provided by widely used viscous dampers. Time history analyses were conducted using seven far‐fault accelerograms and seven near‐fault accelerograms. Seismic performances were evaluated in terms of base shear values, story accelerations, interstory drifts, and story shears. The results indicate that base isolation is highly effective in controlling seismic responses in both far‐fault and near‐fault earthquakes, with average base shear values in the base‐isolated models reduced by approximately 60%–75% compared with the fixed‐base models. Displacements, accelerations, drifts, and story shears were also decreased by more than 50% compared with the fixed‐base models. Base isolation demonstrated acceptable performance in the 4‐, 7‐, and 10‐story models, but supplemental damping was necessary for effective structural control of the 13‐story model in near‐fault earthquakes, as well as the 16‐story and 19‐story models in both far‐fault and near‐fault earthquakes. The incorporation of supplemental damping significantly enhances structural control by further mitigating displacements, shears, and accelerations.

Authors

Institutions

Publication Details

Journal
Shock and Vibration
Published
2025-01-01
DOI
https://doi.org/10.1155/vib/4576020
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Threshold of Need for Supplemental Damping in Seismic Base Isolation of Multistory Buildings

Bertug Ozarisoy, Shahram Derogar, Alireza Babaeian Amini, Peyman Narjabadifam et al.
Shock and Vibration
Seismic Performance and Analysis
article

Assessing the Threshold of Need for Supplemental Damping in Seismic Base Isolation of Multistory Buildings

Bertug Ozarisoy, Shahram Derogar, Alireza Babaeian Amini, Peyman Narjabadifam, Gholam Reza Ostadi Asl, Samad Emamverdi
article en

Abstract

The comprehension of the threshold for the need of supplemental dampers in the base isolation of multistory buildings could be beneficial in the advancement of the application of base isolation to achieve seismic safety. In this study, stick models of 1‐, 4‐, 7‐, 10‐, 13‐, 16‐, and 19‐story buildings were designed in fixed‐base, simply base‐isolated, and damping‐assisted base‐isolated scenarios. The isolation system considered is the well‐known friction pendulum system, with supplemental damping provided by widely used viscous dampers. Time history analyses were conducted using seven far‐fault accelerograms and seven near‐fault accelerograms. Seismic performances were evaluated in terms of base shear values, story accelerations, interstory drifts, and story shears. The results indicate that base isolation is highly effective in controlling seismic responses in both far‐fault and near‐fault earthquakes, with average base shear values in the base‐isolated models reduced by approximately 60%–75% compared with the fixed‐base models. Displacements, accelerations, drifts, and story shears were also decreased by more than 50% compared with the fixed‐base models. Base isolation demonstrated acceptable performance in the 4‐, 7‐, and 10‐story models, but supplemental damping was necessary for effective structural control of the 13‐story model in near‐fault earthquakes, as well as the 16‐story and 19‐story models in both far‐fault and near‐fault earthquakes. The incorporation of supplemental damping significantly enhances structural control by further mitigating displacements, shears, and accelerations.

Shock and VibrationVol. 2025(1)
University of Bonab (IR), London South Bank University (GB), Heriot-Watt University (GB), Boyds (United Kingdom) (GB)
London South Bank University
Sustainable cities and communities
Openalex Percentile: Top 99%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.