Liver Elastography for Liver Fibrosis Stratification: A Comparison of Three Techniques in a Biopsy-Controlled MASLD Cohort

<b>Background:</b> The aim of this study was to investigate the accuracy in fibrosis staging of a novel shear wave elastography (SWE) device (S-Shearwave Imaging by Samsung) and a previously validated 2D-SWE by Supersonic Imagine (SSI) in patients with biopsy proven metabolic dysfunction-associated steatotic liver disease (MASLD). <b>Methods:</b> This prospective study included 75 consecutive patients with MASLD who underwent liver biopsy for suspected MASH. All patients underwent S-Shearwave Imaging by Samsung and 2D-SWE with SSI on the same day of liver biopsy. Fibrosis was histologically assessed using the METAVIR classification system. Agreement between the equipment was assessed with the Pearson coefficient. A receiver operator characteristic curve (ROC) analysis with the Youden index was used to establish thresholds for fibrosis staging. <b>Results:</b> A good correlation was found between S-Shearwave Imaging by Samsung and 2D-SWE with SSI (Pearson's R = 0.68; <i>p</i> < 0.01). At multivariate regression analysis, S-Shearwave Imaging was associated with advanced fibrosis (≥F3) independently from age, diabetes and platelets (OR 2.94, CI 1.69-5.11, <i>p</i> < 0.01). The fibrosis diagnostic accuracy of both S-Shearwave Imaging and 2D-SWE was good to optimal with AUROCs of 0.81 and 0.70 for significant fibrosis (≥F2), 0.94 and 0.91 for severe fibrosis (≥F3), respectively. The accuracy of S-Shearwave is not significantly different from Fibroscan and Agile3+ (DeLong test <i>p</i> value 0.16 and 0.15, respectively) while is slightly better than 2D-SWE, FIB4 and NFS (DeLong test <i>p</i> value < 0.05). For S-Shearwave Imaging by Samsung, the best cut-off values for diagnosing fibrosis ≥F2, ≥F3 were, respectively, 7.9 kPa (Sens 74.4%, Spec 87.5%) and 8.1 kPa (Sens 95.6%, Spec 78.8%). For 2D-SWE by SSI, the best cut-off values for diagnosing fibrosis ≥F2, ≥F3 were, respectively, 7.2 kPa (Sens 55.8%, Spec 84.4%) and 7.6 kPa (Sens 82.6%, Spec 84.6%). <b>Conclusion:</b> S-Shearwave Imaging is a useful and reliable non-invasive technique for staging liver fibrosis in patients with MASLD. Its diagnostic accuracy is non-inferior to other shear wave elastography techniques (TE and 2D-SWE by SSI).

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2025-01-09
DOI
https://doi.org/10.3390/biomedicines13010138
Citations
3
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
4.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Liver Elastography for Liver Fibrosis Stratification: A Comparison of Three Techniques in a Biopsy-Controlled MASLD Cohort

Matteo Garcovich, Maria Cristina Giustiniani, Antonio Gasbarrini, Laura Riccardi et al.
3 citations
Biomedicines
Liver Disease Diagnosis and Treatment
4.06
article

Liver Elastography for Liver Fibrosis Stratification: A Comparison of Three Techniques in a Biopsy-Controlled MASLD Cohort

Matteo Garcovich, Maria Cristina Giustiniani, Antonio Gasbarrini, Laura Riccardi, Maria Assunta Zocco, Mattia Paratore, Raffaele Borriello, Antonio Liguori, Giorgio Esposto, Linda Galasso, Maria Elena Ainora, Luca Miele, Mignini Irene
article en
3 citations

Abstract

<b>Background:</b> The aim of this study was to investigate the accuracy in fibrosis staging of a novel shear wave elastography (SWE) device (S-Shearwave Imaging by Samsung) and a previously validated 2D-SWE by Supersonic Imagine (SSI) in patients with biopsy proven metabolic dysfunction-associated steatotic liver disease (MASLD). <b>Methods:</b> This prospective study included 75 consecutive patients with MASLD who underwent liver biopsy for suspected MASH. All patients underwent S-Shearwave Imaging by Samsung and 2D-SWE with SSI on the same day of liver biopsy. Fibrosis was histologically assessed using the METAVIR classification system. Agreement between the equipment was assessed with the Pearson coefficient. A receiver operator characteristic curve (ROC) analysis with the Youden index was used to establish thresholds for fibrosis staging. <b>Results:</b> A good correlation was found between S-Shearwave Imaging by Samsung and 2D-SWE with SSI (Pearson's R = 0.68; <i>p</i> < 0.01). At multivariate regression analysis, S-Shearwave Imaging was associated with advanced fibrosis (≥F3) independently from age, diabetes and platelets (OR 2.94, CI 1.69-5.11, <i>p</i> < 0.01). The fibrosis diagnostic accuracy of both S-Shearwave Imaging and 2D-SWE was good to optimal with AUROCs of 0.81 and 0.70 for significant fibrosis (≥F2), 0.94 and 0.91 for severe fibrosis (≥F3), respectively. The accuracy of S-Shearwave is not significantly different from Fibroscan and Agile3+ (DeLong test <i>p</i> value 0.16 and 0.15, respectively) while is slightly better than 2D-SWE, FIB4 and NFS (DeLong test <i>p</i> value < 0.05). For S-Shearwave Imaging by Samsung, the best cut-off values for diagnosing fibrosis ≥F2, ≥F3 were, respectively, 7.9 kPa (Sens 74.4%, Spec 87.5%) and 8.1 kPa (Sens 95.6%, Spec 78.8%). For 2D-SWE by SSI, the best cut-off values for diagnosing fibrosis ≥F2, ≥F3 were, respectively, 7.2 kPa (Sens 55.8%, Spec 84.4%) and 7.6 kPa (Sens 82.6%, Spec 84.6%). <b>Conclusion:</b> S-Shearwave Imaging is a useful and reliable non-invasive technique for staging liver fibrosis in patients with MASLD. Its diagnostic accuracy is non-inferior to other shear wave elastography techniques (TE and 2D-SWE by SSI).

BiomedicinesVol. 13(1)
Agostino Gemelli University Polyclinic (IT), Centro Clinico Nemo (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Università Cattolica del Sacro Cuore
Openalex Percentile: Top 8%
Liver Disease Diagnosis and Treatment
4.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.