Evaluation of 3D-Printed Microfluidic Structures for Use in AML-Specific Biomarker Detection of PML::RARA

An obstacle for many microfluidic developments is the fabrication of its structures, which is often complex, time-consuming, and expensive. Additive manufacturing can help to reduce these barriers. This study investigated whether the results of a microfluidic assay for the detection of the promyelocytic leukemia (PML)-retinoic acid receptor α (RARα) fusion protein (PML::RARA), and thus for the differential diagnosis of acute promyelocytic leukemia (APL), could be transferred from borosilicate glass microfluidic structures to additively manufactured fluidics. Digital light processing (DLP) and stereolithography (SLA) printers as well as different photopolymerizable methacrylate-based resins were tested for fabrication of the fluidics. To assess suitability, both print resolution and various physical properties, serializability, biocompatibility, and functionalization with biological molecules were analyzed. The results show that additively manufactured microfluidics are suitable for application in leukemia diagnostics. This was demonstrated by transferring the microfluidic sandwich enzyme-linked immunosorbent assay (ELISA) for PML::RARA onto the surface of magnetic microparticles from a glass structure to three-dimensional (3D)-printed parts. A comparison with conventional glass microstructures suggests lower sensitivity but highlights the potential of additive manufacturing for prototyping microfluidics. This may contribute to the wider use of microfluidics in biotechnological or medical applications.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2025-01-09
DOI
https://doi.org/10.3390/ijms26020497
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of 3D-Printed Microfluidic Structures for Use in AML-Specific Biomarker Detection of PML::RARA

Benedikt Emde, Karsten Niehaus, Lara Tickenbrock
1 citations
International Journal of Molecular Sciences
Advanced biosensing and bioanalysis techniques
0.81
article

Evaluation of 3D-Printed Microfluidic Structures for Use in AML-Specific Biomarker Detection of PML::RARA

Benedikt Emde, Karsten Niehaus, Lara Tickenbrock
article en
1 citations

Abstract

An obstacle for many microfluidic developments is the fabrication of its structures, which is often complex, time-consuming, and expensive. Additive manufacturing can help to reduce these barriers. This study investigated whether the results of a microfluidic assay for the detection of the promyelocytic leukemia (PML)-retinoic acid receptor α (RARα) fusion protein (PML::RARA), and thus for the differential diagnosis of acute promyelocytic leukemia (APL), could be transferred from borosilicate glass microfluidic structures to additively manufactured fluidics. Digital light processing (DLP) and stereolithography (SLA) printers as well as different photopolymerizable methacrylate-based resins were tested for fabrication of the fluidics. To assess suitability, both print resolution and various physical properties, serializability, biocompatibility, and functionalization with biological molecules were analyzed. The results show that additively manufactured microfluidics are suitable for application in leukemia diagnostics. This was demonstrated by transferring the microfluidic sandwich enzyme-linked immunosorbent assay (ELISA) for PML::RARA onto the surface of magnetic microparticles from a glass structure to three-dimensional (3D)-printed parts. A comparison with conventional glass microstructures suggests lower sensitivity but highlights the potential of additive manufacturing for prototyping microfluidics. This may contribute to the wider use of microfluidics in biotechnological or medical applications.

International Journal of Molecular SciencesVol. 26(2)
Bielefeld University (DE), Hamm-Lippstadt University of Applied Sciences (DE)
Openalex Percentile: Top 32%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.