Orientation effect and locational variation in elastic-plastic compressive properties of bovine cortical bone

Bone is a highly heterogeneous and anisotropic material with a hierarchical structure. The effect of diaphysis locations and directions of loading on elastic-plastic compressive properties of bovine femoral cortical bone was examined in this study. The impact of location and loading directions on elastic-plastic compressive properties of cortical bone was found to be statistically insignificant in this study. The variances of most of the compressive properties were also observed to be location and directionality independent except for the locational differences in modulus of resilience (distal to central for longitudinal loading) and plastic work (central to distal for transverse loading) as well as differences in variances of the modulus of resilience and elastic modulus values for two directions of loading. The micro-mechanisms of cortical bone failure for longitudinal and transverse directions of loading were considered to be responsible for the difference in variances in the later properties values as well as for the maximum and minimum coefficient of variation (CV) obtained for compressive properties in two directions of loading. The representative cubical volume at the tested hierarchical level contained all unique microstructural features of the plexiform bone and therefore produced the homogeneous and isotropic elastic-plastic compressive properties of cortical bone. It is expected that the outcome of this study may be helpful in the area of bone tissue engineering and finite element simulation of cortical bone.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2025-01-01
DOI
https://doi.org/10.1177/09544119241308056
Citations
2
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Orientation effect and locational variation in elastic-plastic compressive properties of bovine cortical bone

Sachin Kalsi, Karanvir Saini, N. K. Sharma, Jagjit Singh
2 citations
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Orthopaedic implants and arthroplasty
4.01
article

Orientation effect and locational variation in elastic-plastic compressive properties of bovine cortical bone

Sachin Kalsi, Karanvir Saini, N. K. Sharma, Jagjit Singh
article en
2 citations

Abstract

Bone is a highly heterogeneous and anisotropic material with a hierarchical structure. The effect of diaphysis locations and directions of loading on elastic-plastic compressive properties of bovine femoral cortical bone was examined in this study. The impact of location and loading directions on elastic-plastic compressive properties of cortical bone was found to be statistically insignificant in this study. The variances of most of the compressive properties were also observed to be location and directionality independent except for the locational differences in modulus of resilience (distal to central for longitudinal loading) and plastic work (central to distal for transverse loading) as well as differences in variances of the modulus of resilience and elastic modulus values for two directions of loading. The micro-mechanisms of cortical bone failure for longitudinal and transverse directions of loading were considered to be responsible for the difference in variances in the later properties values as well as for the maximum and minimum coefficient of variation (CV) obtained for compressive properties in two directions of loading. The representative cubical volume at the tested hierarchical level contained all unique microstructural features of the plexiform bone and therefore produced the homogeneous and isotropic elastic-plastic compressive properties of cortical bone. It is expected that the outcome of this study may be helpful in the area of bone tissue engineering and finite element simulation of cortical bone.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineVol. 239(1)
Chandigarh University (IN), University of Saskatchewan (CA), University of Pennsylvania (US)
Openalex Percentile: Top 9%
Orthopaedic implants and arthroplasty
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.