High-Stability and Fast Calibration-Free Temperature Measurement Based on Light-Induced Thermoelastic Spectroscopy

In this paper, a series of calibration-free temperature measurement methods based on light-induced thermoelastic spectroscopy (LITES) are proposed for the first time. These techniques utilize the steady-state and transient response characteristics of the quartz tuning fork (QTF), namely, the calibration-free LITES (CF-LITES) and calibration-free heterodyne LITES (CF-H-LITES) methods. Four methods, first harmonic (1 f ) difference signal to normalize the second harmonic (2 f ) fundamental signal (method I, 2 f fund /1 f diff ), 1 f overtone signal to normalize the 2 f fundamental signal (method II, 2 f fund /1 f over ), 1 f heterodyne difference signal to normalize the 2 f heterodyne fundamental signal (method III, 2 f - H fund /1 f-H diff ), and 1 f heterodyne overtone signal to normalize the 2 f heterodyne fundamental signal (method IV, 2 f-H fund /1 f-H over ), for simultaneously detecting 1 f and 2 f within the frequency response range of the QTF are proposed to achieve calibration-free measurement. A self-designed T-shaped QTF with low fundamental and overtone frequencies was used to increase the energy accumulation time, thereby enhancing the sensor signal level. A 3-stage tube furnace was adopted to verify the performance of these 4 methods. Experimental results showed that the errors for the 4 methods were less than 4%, with a standard deviation below 11 °C. Furthermore, the calibration-free method, which employs normalization of the 2 f signal with the 1 f signal, effectively mitigates the impact of laser beam jitter and power fluctuations on detection performance. A superior performance can be obtained by adopting the CF-H-LITES technique based on method IV. It not only has excellent detection performance but also reduces the measurement period to 4 s, which is about 5 times faster. This development shows substantial promise for expanding the application of the CF-LITES and CF-H-LITES techniques in harsh environments.

Authors

Institutions

Publication Details

Journal
Ultrafast Science
Published
2025-01-01
DOI
https://doi.org/10.34133/ultrafastscience.0083
Citations
25
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
16.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Stability and Fast Calibration-Free Temperature Measurement Based on Light-Induced Thermoelastic Spectroscopy

Ying He, Yufei Ma, Xiaonan Liu, Shunda Qiao
25 citations
Ultrafast Science
Advanced Sensor Technologies Research
16.85
article

High-Stability and Fast Calibration-Free Temperature Measurement Based on Light-Induced Thermoelastic Spectroscopy

Ying He, Yufei Ma, Xiaonan Liu, Shunda Qiao
article en
25 citations

Abstract

In this paper, a series of calibration-free temperature measurement methods based on light-induced thermoelastic spectroscopy (LITES) are proposed for the first time. These techniques utilize the steady-state and transient response characteristics of the quartz tuning fork (QTF), namely, the calibration-free LITES (CF-LITES) and calibration-free heterodyne LITES (CF-H-LITES) methods. Four methods, first harmonic (1 f ) difference signal to normalize the second harmonic (2 f ) fundamental signal (method I, 2 f fund /1 f diff ), 1 f overtone signal to normalize the 2 f fundamental signal (method II, 2 f fund /1 f over ), 1 f heterodyne difference signal to normalize the 2 f heterodyne fundamental signal (method III, 2 f - H fund /1 f-H diff ), and 1 f heterodyne overtone signal to normalize the 2 f heterodyne fundamental signal (method IV, 2 f-H fund /1 f-H over ), for simultaneously detecting 1 f and 2 f within the frequency response range of the QTF are proposed to achieve calibration-free measurement. A self-designed T-shaped QTF with low fundamental and overtone frequencies was used to increase the energy accumulation time, thereby enhancing the sensor signal level. A 3-stage tube furnace was adopted to verify the performance of these 4 methods. Experimental results showed that the errors for the 4 methods were less than 4%, with a standard deviation below 11 °C. Furthermore, the calibration-free method, which employs normalization of the 2 f signal with the 1 f signal, effectively mitigates the impact of laser beam jitter and power fluctuations on detection performance. A superior performance can be obtained by adopting the CF-H-LITES technique based on method IV. It not only has excellent detection performance but also reduces the measurement period to 4 s, which is about 5 times faster. This development shows substantial promise for expanding the application of the CF-LITES and CF-H-LITES techniques in harsh environments.

Ultrafast ScienceVol. 5
Harbin Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 1%
Advanced Sensor Technologies Research
16.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.