Design and Validation Strategy for an X-Ray Target Subject to Ultra High Heat Flux Loading

Abstract Microbeam X-ray therapy is a promising cancer therapy that uses a high-power electron beam hitting a metallic target. For a clinical microbeam therapy X-ray source, an electron beam of a power of 1 MW onto a focal spot of 0.05 mm × 20 mm size is needed, with a penetration depth of 0.1 mm. This means a heat flux input of 1 TW/m2, an order of magnitude higher than nuclear and medical applications. Numerical simulations based on surface and volumetric heat loading for such an electron beam are presented in this work. The local temperature around the focal spot is modeled in a lower-scale model with an element size of 10 µm and volumetric heat loading. This differs from the state-of-the-art simulations, in which electron beam loading is modeled as surface heat flux loads. The simulated temperature agrees with the mathematical estimates within an error of 10% while proving feasibility. A novel validation strategy is proposed to address the lack of available test facilities to replicate this extreme heat flux. The critical parameters describing the high-heat-flux-loading are identified as temperature, thermal strain, thermal stress, and strain rate. Scaled-down test specifications are determined to use a test facility of power less than 100 kW. With the verified simulation using the scaled-down test, it is proposed to establish the material's capability to withstand the concentrated 1 MW heat load without a 1 MW test facility.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2025-01-09
DOI
https://doi.org/10.1115/1.4067589
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Validation Strategy for an X-Ray Target Subject to Ultra High Heat Flux Loading

Anton Dimroth, Markus Zimmermann, Kim Melanie Kraus, Johanna Winter et al.
Journal of Thermal Science and Engineering Applications
Nuclear Physics and Applications
article

Design and Validation Strategy for an X-Ray Target Subject to Ultra High Heat Flux Loading

Anton Dimroth, Markus Zimmermann, Kim Melanie Kraus, Johanna Winter, Stefan Bartzsch, Mahadevan Ravichandran
article en

Abstract

Abstract Microbeam X-ray therapy is a promising cancer therapy that uses a high-power electron beam hitting a metallic target. For a clinical microbeam therapy X-ray source, an electron beam of a power of 1 MW onto a focal spot of 0.05 mm × 20 mm size is needed, with a penetration depth of 0.1 mm. This means a heat flux input of 1 TW/m2, an order of magnitude higher than nuclear and medical applications. Numerical simulations based on surface and volumetric heat loading for such an electron beam are presented in this work. The local temperature around the focal spot is modeled in a lower-scale model with an element size of 10 µm and volumetric heat loading. This differs from the state-of-the-art simulations, in which electron beam loading is modeled as surface heat flux loads. The simulated temperature agrees with the mathematical estimates within an error of 10% while proving feasibility. A novel validation strategy is proposed to address the lack of available test facilities to replicate this extreme heat flux. The critical parameters describing the high-heat-flux-loading are identified as temperature, thermal strain, thermal stress, and strain rate. Scaled-down test specifications are determined to use a test facility of power less than 100 kW. With the verified simulation using the scaled-down test, it is proposed to establish the material's capability to withstand the concentrated 1 MW heat load without a 1 MW test facility.

Journal of Thermal Science and Engineering ApplicationsVol. 17(3)
Forschungszentrum Jülich (DE), TUM Klinikum (DE), Helmholtz Zentrum München (DE), Max Planck Computing and Data Facility (DE), Technical Design (United States) (US)
Australian Government, Bundesministerium für Bildung und Forschung, Technische Universität München
Affordable and clean energy
Openalex Percentile: Top 99%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.