Test‐retest reliability of FreeSurfer measures of neurodegeneration

Abstract Background FreeSurfer is widely used for monitoring neurodegeneration by quantifying MRI brain regions vulnerable to atrophic changes associated with Alzheimer’s disease (AD). FreeSurfer test‐retest reliability has been explored mainly in younger adults, but the reliability of AD imaging biomarkers is less well studied. We used two closely spaced T1‐weighted MRIs in 100 older adults to assess FreeSurfer 7.1 test‐retest reliability of AD imaging biomarkers of neurodegeneration. Method Consecutive participants (n=100, age ≥60 years) with two brain MRI exams between Jan 2021 and Oct 2023 and less than 180 days between exams were selected from NYU Langone’s Alzheimer Disease Research Center database. Images were acquired on the same Siemens 3T PET‐MR system using 32‐channel head coil and sagittal T1‐weighted MPRAGE sequence (TR=2100ms; TE=2.98ms; TI=900ms; FA=8°; bandwidth, 260Hz/pixel; GRAPPA, 2; matrix, 256x240x176; voxel, 1x1x1 mm 3 ; acquisition time, 4:35min). FreeSurfer 7.1 was used to segment the brain and determine regional volumes, cortical thickness, and intracranial volume (ICV). We compared bilateral and total hippocampal volume, entorhinal cortex thickness, AD signature (after Dickerson et al. Cereb Cortex 2009; PMID: 18632739), and ICV between two exams. Test‐retest reliability was assessed using mean absolute difference, root mean square difference, and intraclass correlation coefficient (ICC). Inter‐exam differences in AD measures were tested for association with demographic, cognitive (MOCA), and imaging features using linear regression. Result The 100 participants (age, 73.5±6.1 years, 64% women, 33% Black, 9‐20 years education) had MRIs within an interval of 5.5±5.2 weeks (Figure 1). FreeSurfer estimates of MRI‐based biomarkers of AD were consistent between exams (Table 1). There were no associations between the differences in any of the FreeSurfer measures and inter‐MRI interval or participants’ demographic and cognitive/biological features (Figure 2). Detecting within‐individual 1% change in AD signature, whole hippocampus, or entorhinal cortex (using paired t‐test) at p=0.05 and 80% power, would require an estimated sample of 38, 69, or 347 subjects, respectively. Conclusion Our test‐retest results reflect random errors due to image acquisition and post‐processing precision of FreeSurfer 7.1. The test‐retest reliability of most measures is excellent, except entorhinal cortex thickness. Detecting small neurodegenerative changes appears to be feasible with relatively small sample sizes.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.085368
Primary Topic
S100 Proteins and Annexins
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test‐retest reliability of FreeSurfer measures of neurodegeneration

Arjun V. Masurkar, Louisa Bokacheva, Henry Rusinek, Ricardo S. Osorio et al.
1 links
Alzheimer s & Dementia
S100 Proteins and Annexins
article

Test‐retest reliability of FreeSurfer measures of neurodegeneration

Arjun V. Masurkar, Louisa Bokacheva, Henry Rusinek, Ricardo S. Osorio, Alok Vedvyas, Thomas Wısnıewskı, Haiyun Chen
article en

Abstract

Abstract Background FreeSurfer is widely used for monitoring neurodegeneration by quantifying MRI brain regions vulnerable to atrophic changes associated with Alzheimer’s disease (AD). FreeSurfer test‐retest reliability has been explored mainly in younger adults, but the reliability of AD imaging biomarkers is less well studied. We used two closely spaced T1‐weighted MRIs in 100 older adults to assess FreeSurfer 7.1 test‐retest reliability of AD imaging biomarkers of neurodegeneration. Method Consecutive participants (n=100, age ≥60 years) with two brain MRI exams between Jan 2021 and Oct 2023 and less than 180 days between exams were selected from NYU Langone’s Alzheimer Disease Research Center database. Images were acquired on the same Siemens 3T PET‐MR system using 32‐channel head coil and sagittal T1‐weighted MPRAGE sequence (TR=2100ms; TE=2.98ms; TI=900ms; FA=8°; bandwidth, 260Hz/pixel; GRAPPA, 2; matrix, 256x240x176; voxel, 1x1x1 mm 3 ; acquisition time, 4:35min). FreeSurfer 7.1 was used to segment the brain and determine regional volumes, cortical thickness, and intracranial volume (ICV). We compared bilateral and total hippocampal volume, entorhinal cortex thickness, AD signature (after Dickerson et al. Cereb Cortex 2009; PMID: 18632739), and ICV between two exams. Test‐retest reliability was assessed using mean absolute difference, root mean square difference, and intraclass correlation coefficient (ICC). Inter‐exam differences in AD measures were tested for association with demographic, cognitive (MOCA), and imaging features using linear regression. Result The 100 participants (age, 73.5±6.1 years, 64% women, 33% Black, 9‐20 years education) had MRIs within an interval of 5.5±5.2 weeks (Figure 1). FreeSurfer estimates of MRI‐based biomarkers of AD were consistent between exams (Table 1). There were no associations between the differences in any of the FreeSurfer measures and inter‐MRI interval or participants’ demographic and cognitive/biological features (Figure 2). Detecting within‐individual 1% change in AD signature, whole hippocampus, or entorhinal cortex (using paired t‐test) at p=0.05 and 80% power, would require an estimated sample of 38, 69, or 347 subjects, respectively. Conclusion Our test‐retest results reflect random errors due to image acquisition and post‐processing precision of FreeSurfer 7.1. The test‐retest reliability of most measures is excellent, except entorhinal cortex thickness. Detecting small neurodegenerative changes appears to be feasible with relatively small sample sizes.

Alzheimer s & DementiaVol. 20(S2)
NYU Langone Health (US), New York University (US)
Openalex Percentile: Top 78%
S100 Proteins and Annexins
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.