Accuracy of the Dexcom G7 Continuous Glucose Monitoring Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA-2 Study)

The accuracy of the latest generation Dexcom G7 sensors in individuals with diabetes undergoing hemodialysis has not previously been investigated. Participants with diabetes undergoing hemodialysis were recruited, with paired sensor glucose from Dexcom G7 recorded with plasma glucose analyzed in the laboratory, as well as the Freestyle Precision Pro glucometer and EKF Biosen C-Line analyzer. Ten adults (median age 64.0 [58.0-74.5] years) were recruited. Overall percentage (%) mean and median absolute relative differences were 10.4% and 8.5% for matched laboratory pairs, respectively (<i>n</i> = 720). Diabetes Technology Society error grid analysis showed 99.7%, 100%, and 99.9% of pairs within zones A and B for lab, glucometer, and EKF methods, respectively. This, the first Dexcom G7 accuracy study conducted in people on hemodialysis, demonstrates accuracy and safety when compared with lab reference readings. These data support the accessibility of continuous glucose monitoring (CGM) and hybrid closed-loop systems for people with diabetes on hemodialysis.

Authors

Institutions

Publication Details

Journal
Diabetes Technology & Therapeutics
Published
2025-01-09
DOI
https://doi.org/10.1089/dia.2024.0575
Citations
8
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
10.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of the Dexcom G7 Continuous Glucose Monitoring Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA-2 Study)

Monika Reddy, Tricia Tan, Parizad Avari, Lalantha Leelarathna et al.
8 citations
Diabetes Technology & Therapeutics
Diabetes Management and Research
10.36
article

Accuracy of the Dexcom G7 Continuous Glucose Monitoring Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA-2 Study)

Monika Reddy, Tricia Tan, Parizad Avari, Lalantha Leelarathna, Nick S. Oliver, Andrew Frankel, Reshaba Pushparatnam
article en
8 citations

Abstract

The accuracy of the latest generation Dexcom G7 sensors in individuals with diabetes undergoing hemodialysis has not previously been investigated. Participants with diabetes undergoing hemodialysis were recruited, with paired sensor glucose from Dexcom G7 recorded with plasma glucose analyzed in the laboratory, as well as the Freestyle Precision Pro glucometer and EKF Biosen C-Line analyzer. Ten adults (median age 64.0 [58.0-74.5] years) were recruited. Overall percentage (%) mean and median absolute relative differences were 10.4% and 8.5% for matched laboratory pairs, respectively (<i>n</i> = 720). Diabetes Technology Society error grid analysis showed 99.7%, 100%, and 99.9% of pairs within zones A and B for lab, glucometer, and EKF methods, respectively. This, the first Dexcom G7 accuracy study conducted in people on hemodialysis, demonstrates accuracy and safety when compared with lab reference readings. These data support the accessibility of continuous glucose monitoring (CGM) and hybrid closed-loop systems for people with diabetes on hemodialysis.

Diabetes Technology & TherapeuticsVol. 27(5)
Imperial College Healthcare NHS Trust (GB), Imperial College London (GB)
Zero hunger
Openalex Percentile: Top 2%
Diabetes Management and Research
10.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of the Dexcom G7 Continuous Glucose Monitoring Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA-2 Study) — Monika Reddy, Tricia Tan, et al. · Diabetes Technology & Therapeutics (2025) | TGRS Research Map | TGRS