Impact of Dynamic Voltage Support of Large-scale PV Plants on Frequency Stability in the Senegalese Power System

In modern grid codes, non-synchronous power plants are required to provide dynamic voltage support (DVS) to preserve the grid stability in the event of a fault. However, this function remains to be explicitly defined for LSPVPs in the Senegalese power system (SPS), and is subject of investigation in this paper. The impact of enabling the DVS in large-scale photovoltaic plants (LSPVPs) is compared to the momentary cessation mode during low voltage ride-through (LVRT) on power system voltage and frequency stability. As case study, the Senegalese power system is simulated in PowerFactory software. The results demonstrate that enabling DVS strengthens the point of interconnection and prevents the disconnection of large-scale PV plants during transmission line faults. Furthermore, the implementation of DVS improves the frequency stability while increasing the share of large-scale PV penetration in the power system. For a total wind and LSPVPs penetration of 55.7 %, the frequency nadir is enhanced by 1.48 % and the steady-state frequency deviation by 0.9 %. At a penetration rate of 66.8 %, the DVS of LSPVPs avoids triggering underfrequency load shedding; and improve the frequency nadir and the steady-state frequency deviation a by 4.17% and 1.5%, respectively.

Authors

Institutions

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.1109/powerafrica61624.2024.10759504
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Dynamic Voltage Support of Large-scale PV Plants on Frequency Stability in the Senegalese Power System

Ousmane Manga Adamou, Lamine Thiaw, Martin Wolter, Ababacar Niang et al.
Optimal Power Flow Distribution
article

Impact of Dynamic Voltage Support of Large-scale PV Plants on Frequency Stability in the Senegalese Power System

Ousmane Manga Adamou, Lamine Thiaw, Martin Wolter, Ababacar Niang, Ndeye Khady Diop Dieng
article en

Abstract

In modern grid codes, non-synchronous power plants are required to provide dynamic voltage support (DVS) to preserve the grid stability in the event of a fault. However, this function remains to be explicitly defined for LSPVPs in the Senegalese power system (SPS), and is subject of investigation in this paper. The impact of enabling the DVS in large-scale photovoltaic plants (LSPVPs) is compared to the momentary cessation mode during low voltage ride-through (LVRT) on power system voltage and frequency stability. As case study, the Senegalese power system is simulated in PowerFactory software. The results demonstrate that enabling DVS strengthens the point of interconnection and prevents the disconnection of large-scale PV plants during transmission line faults. Furthermore, the implementation of DVS improves the frequency stability while increasing the share of large-scale PV penetration in the power system. For a total wind and LSPVPs penetration of 55.7 %, the frequency nadir is enhanced by 1.48 % and the steady-state frequency deviation by 0.9 %. At a penetration rate of 66.8 %, the DVS of LSPVPs avoids triggering underfrequency load shedding; and improve the frequency nadir and the steady-state frequency deviation a by 4.17% and 1.5%, respectively.

Université Abdou Moumouni (NE), Otto-von-Guericke-Universität Magdeburg (DE), Cheikh Anta Diop University (SN)
Affordable and clean energy
Openalex Percentile: Top 77%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.