Life-cycle cost analysis of electricity backup solutions: a South African case study

Load-shedding has emerged as one of the major crises in South Africa, disrupting the daily lives and economic activities of its citizens. The persistent power outages and frequent blackouts pose a significant challenge in public hospitals, impacting various stakeholders and hindering the ability of these institutions to provide timely services to the community. This study uses a life cycle cost analysis of two electricity back-up options to assess and recommend the most viable option. The research utilizes the case of one of the largest healthcare facilities in the Mpumalanga Province, and compares the efficacy of two electricity backup options, namely photovoltaic Solar and diesel generators. The simulation of PV Solar and diesel generator configurations and cost estimation were conducted using Homer Pro software. The findings indicate that the PV Solar system outperforms the diesel generator, offering a significantly lower life cycle cost that is approximately two times less than that of the diesel generator. The findings of this study provide factual decision-making apparatus to business leaders on the viability of the different options available as back-up when load-shedding is in effect.

Authors

Institutions

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.1109/powerafrica61624.2024.10759449
Primary Topic
Life Cycle Costing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Life-cycle cost analysis of electricity backup solutions: a South African case study

Tebello N.D. Mathaba, M. E. Letoaba, BMB Cebekhulu
Life Cycle Costing Analysis
article

Life-cycle cost analysis of electricity backup solutions: a South African case study

Tebello N.D. Mathaba, M. E. Letoaba, BMB Cebekhulu
article en

Abstract

Load-shedding has emerged as one of the major crises in South Africa, disrupting the daily lives and economic activities of its citizens. The persistent power outages and frequent blackouts pose a significant challenge in public hospitals, impacting various stakeholders and hindering the ability of these institutions to provide timely services to the community. This study uses a life cycle cost analysis of two electricity back-up options to assess and recommend the most viable option. The research utilizes the case of one of the largest healthcare facilities in the Mpumalanga Province, and compares the efficacy of two electricity backup options, namely photovoltaic Solar and diesel generators. The simulation of PV Solar and diesel generator configurations and cost estimation were conducted using Homer Pro software. The findings indicate that the PV Solar system outperforms the diesel generator, offering a significantly lower life cycle cost that is approximately two times less than that of the diesel generator. The findings of this study provide factual decision-making apparatus to business leaders on the viability of the different options available as back-up when load-shedding is in effect.

University of Johannesburg (ZA)
Responsible consumption and production
Openalex Percentile: Top 58%
Life Cycle Costing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.