Analysis of GIS Insulation Fault Characteristics under VFTO

Basin insulators are one of the rare faults with high probability in GIS equipment, especially the surface flashover of basin insulators, which poses a great threat to the safety of GIS operation. This article analyzes the II bus fault that occurred in the 220 kV GIS substation. Through the fault waveform and equipment damage, it was found that the fault was caused by the operating overvoltage generated when the circuit breaker was closed. To further analyze the fault, this article established an electric field simulation model to conduct electric field simulation analysis on the GIS bus under operating overvoltage and short-circuit grounding faults. The results indicate that the asymmetry of the bowl-shaped insulator structure exacerbates the occurrence of faults, and overvoltage and short-circuit grounding during operation lead to insulator breakdown.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/sges63808.2024.10824206
Primary Topic
Geological Modeling and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of GIS Insulation Fault Characteristics under VFTO

Xixiu Wu, Huan Wang, Hongbin Li
Geological Modeling and Analysis
article

Analysis of GIS Insulation Fault Characteristics under VFTO

Xixiu Wu, Huan Wang, Hongbin Li
article en

Abstract

Basin insulators are one of the rare faults with high probability in GIS equipment, especially the surface flashover of basin insulators, which poses a great threat to the safety of GIS operation. This article analyzes the II bus fault that occurred in the 220 kV GIS substation. Through the fault waveform and equipment damage, it was found that the fault was caused by the operating overvoltage generated when the circuit breaker was closed. To further analyze the fault, this article established an electric field simulation model to conduct electric field simulation analysis on the GIS bus under operating overvoltage and short-circuit grounding faults. The results indicate that the asymmetry of the bowl-shaped insulator structure exacerbates the occurrence of faults, and overvoltage and short-circuit grounding during operation lead to insulator breakdown.

Wuhan University of Technology (CN), Huazhong University of Science and Technology (CN)
Climate action
Openalex Percentile: Top 76%
Geological Modeling and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.