Research on an Optimal Design of DSOGI-PLL Based on Complex Power Grid

The complexity of modern power systems, attributed to electronic integration and nonlinear loads, intensifies harmonic pollution and power quality problems. Effective management necessitates real-time detection of the grid phase and frequency utilizing PLLs. The dual second-order generalized integrator phase-locked loop (DSOGI-PLL), renowned for its minimal overshoot and delay, lacks adequate filtering capacity in complex grids and is sensitive to DC components. This paper optimizes the SOGI within the traditional DSOGI-PLL, enhancing its resistance to high and low frequency interference. Additionally, a Double Cascade Optimized Sliding Average Filter (DCO-MAF) based on the Moving Average Filter (MAF) is introduced to eliminate grid harmonics with minimal delay, enabling swift and accurate PLL synchronization. Simulation results employing MATLAB/Simulink demonstrate that the optimized design significantly outperforms the traditional DSOGI-PLL in conditions with DC offsets or harmonics, showcasing its robustness and effectiveness.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/pepsc63375.2024.10823490
Citations
2
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on an Optimal Design of DSOGI-PLL Based on Complex Power Grid

Jiaxin Xu, Yufeng Dai, Qiong Wu, Dayi Li et al.
2 citations
Power Systems and Technologies
0.42
article

Research on an Optimal Design of DSOGI-PLL Based on Complex Power Grid

Jiaxin Xu, Yufeng Dai, Qiong Wu, Dayi Li, Tiantian Cao, Zhengyang Ye
article en
2 citations

Abstract

The complexity of modern power systems, attributed to electronic integration and nonlinear loads, intensifies harmonic pollution and power quality problems. Effective management necessitates real-time detection of the grid phase and frequency utilizing PLLs. The dual second-order generalized integrator phase-locked loop (DSOGI-PLL), renowned for its minimal overshoot and delay, lacks adequate filtering capacity in complex grids and is sensitive to DC components. This paper optimizes the SOGI within the traditional DSOGI-PLL, enhancing its resistance to high and low frequency interference. Additionally, a Double Cascade Optimized Sliding Average Filter (DCO-MAF) based on the Moving Average Filter (MAF) is introduced to eliminate grid harmonics with minimal delay, enabling swift and accurate PLL synchronization. Simulation results employing MATLAB/Simulink demonstrate that the optimized design significantly outperforms the traditional DSOGI-PLL in conditions with DC offsets or harmonics, showcasing its robustness and effectiveness.

Huazhong University of Science and Technology (CN)
National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 36%
Power Systems and Technologies
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.