Nonzero Data-Filtering-Based Photoacoustic Image Reconstruction: Both for Microscopy and Tomography

Images, not necessarily to be photoacoustic (PA), are conventionally reconstructed from a collection of boundary-measured data that are also comprised of a significantly large percentage of background noisy signals delivering no pertaining information, and thus, the obtainable imaging performance is remarkably degraded. This article presents a novel and unique technique to undertake image reconstruction, taking into account only the selective signals of importance while filtering out the unwanted noisy signals selectively, that immensely enhances the achievable image quality. Quantitative validation studies − both simulations and experiments in diversified samples (agars, leaf-veins, and excised tissues (chicken-breasts)) using our home-built photoacoustic imaging (PAI) modalities both tomography (PAT) and microscopy (PAM) − demonstrate a significant enhancement in the imaging performance that are quantified in terms of various statistical parameters of great interest in practical clinical applications, say, signal-to-noise-ratio (SNR) (~ 25-94%), contrast-ratio (CR) (~ 164-189%), axial-resolution (~ 40-49%), and lateral-resolution (~ 27-62%).

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3527493
Citations
3
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonzero Data-Filtering-Based Photoacoustic Image Reconstruction: Both for Microscopy and Tomography

Deepayan Samanta, Arijit Paramanick, Mayanglambam Suheshkumar Singh
3 citations
IEEE Transactions on Instrumentation and Measurement
Photoacoustic and Ultrasonic Imaging
2.02
article

Nonzero Data-Filtering-Based Photoacoustic Image Reconstruction: Both for Microscopy and Tomography

Deepayan Samanta, Arijit Paramanick, Mayanglambam Suheshkumar Singh
article en
3 citations

Abstract

Images, not necessarily to be photoacoustic (PA), are conventionally reconstructed from a collection of boundary-measured data that are also comprised of a significantly large percentage of background noisy signals delivering no pertaining information, and thus, the obtainable imaging performance is remarkably degraded. This article presents a novel and unique technique to undertake image reconstruction, taking into account only the selective signals of importance while filtering out the unwanted noisy signals selectively, that immensely enhances the achievable image quality. Quantitative validation studies − both simulations and experiments in diversified samples (agars, leaf-veins, and excised tissues (chicken-breasts)) using our home-built photoacoustic imaging (PAI) modalities both tomography (PAT) and microscopy (PAM) − demonstrate a significant enhancement in the imaging performance that are quantified in terms of various statistical parameters of great interest in practical clinical applications, say, signal-to-noise-ratio (SNR) (~ 25-94%), contrast-ratio (CR) (~ 164-189%), axial-resolution (~ 40-49%), and lateral-resolution (~ 27-62%).

IEEE Transactions on Instrumentation and MeasurementVol. 74
Indian Institute of Science Education and Research Thiruvananthapuram (IN)
Douglas Bomford Trust
Openalex Percentile: Top 16%
Photoacoustic and Ultrasonic Imaging
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.