Repeat Testing Reliability of Plasma pTau217 in Preclinical AD

Abstract Background Data from the Anti‐Amyloid Treatment in Asymptomatic Alzheimer's Disease (A4) trial (NCT02008357), including cognitively unimpaired participants with brain amyloid pathology on florbetapir F 18, demonstrates that levels of plasma P‐tau217, as detected by an electrochemiluminescence (ECL) immunoassay, is strong predictor of elevated cerebral amyloid on florbetapir PET in cognitively unimpaired individuals. Here we compare plasma P‐tau217 measures over 12 weeks using a P‐tau217 ECL immunoassay. Method A4 trial placebo‐group participants who had their first baseline and first post‐baseline plasma P‐tau217 samples collected within 175 days of each other were included in these analyses. This time was chosen to maximize the number of available samples while minimizing the likelihood of significant change. The coefficient of variation (CV) was used to measure relative variability between samples computed as the difference in plasma P‐tau217 values, and the “test‐retest” performance of the plasma P‐tau217 assay was evaluated using an intraclass correlation coefficient (ICC) from a two‐way mixed‐effects model. A Box‐Cox data transform was performed due to significant observed heteroscedasticity in the P‐tau217 values. Result Analysis sample included 573 A4 study participants (mean age: 71.9 +/‐ 5 years, mean florbetapir SUVr: 1.33 +/‐ 0.18; days between assays: 86.5 +/‐ 6.5 days; 59.9% female sex). Low levels of variability were observed between the samples with a coefficient of variation of 7% and the test‐retest reliability was ICC=0.90 (ICC: 0.90; 95% CI: 0.89, 0.92). Conclusion A P‐tau217 ECL immunoassay showed low levels of variability between samples and excellent test‐retest reliability over 12 weeks in cognitively unimpaired individuals with elevated cerebral amyloid.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.092759
Primary Topic
Pharmacological Effects and Toxicity Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeat Testing Reliability of Plasma pTau217 in Preclinical AD

Oliver Langford, Karen C. Holdridge, Robert A. Rissman, Keith A. Johnson et al.
1 links
Alzheimer s & Dementia
Pharmacological Effects and Toxicity Studies
article

Repeat Testing Reliability of Plasma pTau217 in Preclinical AD

Oliver Langford, Karen C. Holdridge, Robert A. Rissman, Keith A. Johnson, Michael Donohue, Sara Abdel‐Latif, Rema Raman, Doris P. Molina‐Henry, Paul Aisen, R. Yaari, Reisa A Sperling, John R. Sims
article en

Abstract

Abstract Background Data from the Anti‐Amyloid Treatment in Asymptomatic Alzheimer's Disease (A4) trial (NCT02008357), including cognitively unimpaired participants with brain amyloid pathology on florbetapir F 18, demonstrates that levels of plasma P‐tau217, as detected by an electrochemiluminescence (ECL) immunoassay, is strong predictor of elevated cerebral amyloid on florbetapir PET in cognitively unimpaired individuals. Here we compare plasma P‐tau217 measures over 12 weeks using a P‐tau217 ECL immunoassay. Method A4 trial placebo‐group participants who had their first baseline and first post‐baseline plasma P‐tau217 samples collected within 175 days of each other were included in these analyses. This time was chosen to maximize the number of available samples while minimizing the likelihood of significant change. The coefficient of variation (CV) was used to measure relative variability between samples computed as the difference in plasma P‐tau217 values, and the “test‐retest” performance of the plasma P‐tau217 assay was evaluated using an intraclass correlation coefficient (ICC) from a two‐way mixed‐effects model. A Box‐Cox data transform was performed due to significant observed heteroscedasticity in the P‐tau217 values. Result Analysis sample included 573 A4 study participants (mean age: 71.9 +/‐ 5 years, mean florbetapir SUVr: 1.33 +/‐ 0.18; days between assays: 86.5 +/‐ 6.5 days; 59.9% female sex). Low levels of variability were observed between the samples with a coefficient of variation of 7% and the test‐retest reliability was ICC=0.90 (ICC: 0.90; 95% CI: 0.89, 0.92). Conclusion A P‐tau217 ECL immunoassay showed low levels of variability between samples and excellent test‐retest reliability over 12 weeks in cognitively unimpaired individuals with elevated cerebral amyloid.

Alzheimer s & DementiaVol. 20(S2)
University of Southern California (US), Brigham and Women's Hospital (US), Harvard University (US), Eli Lilly (United States) (US), Gordon Center for Medical Imaging (US), Massachusetts General Hospital (US)
Openalex Percentile: Top 61%
Pharmacological Effects and Toxicity Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.