A Self-Contained Calibration Scheme for Micro-CT With Irregular Trajectories Based on Phantom Auto-Measurement

Cone-beam CT (CBCT) with irregular trajectories has been widely used in various fields such as clinical medicine and scientific research. Precise geometric calibration is a crucial prerequisite for determining the imaging quality of these systems. Current primary calibration methods rely on highly accurate geometric phantoms with complex patterns. However, to reduce the reliance on manufacturing these phantoms with specialized equipment, a common alternative method is to use a well-calibrated CBCT system with a matching resolution to measure the phantom. However, when calibrating high-resolution CBCT (Micro CT) with irregular trajectories using this strategy, finding a Micro CT with a matching resolution and field of view is often inconvenient, and may even be challenging when the desired Micro CT resolution exceeds the available ones. To address this issue, we propose a method for measuring phantoms based on uncalibrated systems with irregular trajectories. This method is based on a non-convex model constructed with multiple projection views and multiple coordinate systems. After solving the non-convex model efficiently by using the proposed simulated annealing algorithm with a hook, the phantom can be measured accurately. The advantage of this method is that it does not rely on a third-party well-calibrated Micro CT system and enables precise measurements of phantoms using the desired uncalibrated system itself. Consequently, by combining existing geometric calibration algorithms, we can achieve self-contained calibration independent of third-party measurement or manufacturing instruments. This significantly simplifies the dependence on objective conditions during the geometric calibration process for Micro CT systems with irregular trajectories.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3527524
Citations
3
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
4.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Self-Contained Calibration Scheme for Micro-CT With Irregular Trajectories Based on Phantom Auto-Measurement

Xu Ji, Guang Li, H. J. Wang, Shouhua Luo et al.
3 citations
IEEE Transactions on Instrumentation and Measurement
Medical Imaging Techniques and Applications
4.08
article

A Self-Contained Calibration Scheme for Micro-CT With Irregular Trajectories Based on Phantom Auto-Measurement

Xu Ji, Guang Li, H. J. Wang, Shouhua Luo, Yang Chen, Xue Chen, X. T. Huang, Langrui Zhou
article en
3 citations

Abstract

Cone-beam CT (CBCT) with irregular trajectories has been widely used in various fields such as clinical medicine and scientific research. Precise geometric calibration is a crucial prerequisite for determining the imaging quality of these systems. Current primary calibration methods rely on highly accurate geometric phantoms with complex patterns. However, to reduce the reliance on manufacturing these phantoms with specialized equipment, a common alternative method is to use a well-calibrated CBCT system with a matching resolution to measure the phantom. However, when calibrating high-resolution CBCT (Micro CT) with irregular trajectories using this strategy, finding a Micro CT with a matching resolution and field of view is often inconvenient, and may even be challenging when the desired Micro CT resolution exceeds the available ones. To address this issue, we propose a method for measuring phantoms based on uncalibrated systems with irregular trajectories. This method is based on a non-convex model constructed with multiple projection views and multiple coordinate systems. After solving the non-convex model efficiently by using the proposed simulated annealing algorithm with a hook, the phantom can be measured accurately. The advantage of this method is that it does not rely on a third-party well-calibrated Micro CT system and enables precise measurements of phantoms using the desired uncalibrated system itself. Consequently, by combining existing geometric calibration algorithms, we can achieve self-contained calibration independent of third-party measurement or manufacturing instruments. This significantly simplifies the dependence on objective conditions during the geometric calibration process for Micro CT systems with irregular trajectories.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Ministry of Education (BD), Southeast University (CN)
National Natural Science Foundation of China, Jiangsu Provincial Key Research and Development Program, National Key Research and Development Program of China
Openalex Percentile: Top 8%
Medical Imaging Techniques and Applications
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.