Development of an algorithm for detecting rotor bar breakage in an induction generator
The use of self-excited induction generators for power generation is receiving particular attention due to their various advantages, including reduced maintenance costs and greater reliability compared with traditional generators. What’s more, their self-excitation capability enhances the energy efficiency of power generation systems. During operation, the self-excited induction generator may experience one or more faults that could have an impact on its performance. This article presents a study of the induction generator in a healthy state and discusses the presence of rotor bar fracture faults. We aim to develop a monitoring strategy to rapidly detect the presence of the fault as soon as it occurs. This monitoring strategy will be based on the spectral analysis of the generator’s stator current, a technique which has already demonstrated its effectiveness in the early detection of faults.
Authors
- Radia Abdelli
- Ahcène Bouzida (ORCID: https://orcid.org/0000-0002-3485-2194)
- Belynda Fares
Institutions
- University of Béjaïa (DZ)
- University of Bouira (DZ)
Publication Details
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1109/icaecot62402.2024.10828597
- Primary Topic
- Engineering Diagnostics and Reliability
- Type
- article
- Field-Weighted Citation Impact
- 0.00