Wavelength-Resolved Magnetic Multiplex Biosensor for Simultaneous and Ultrasensitive Detection of Pneumonia Pathogens via Catalytic Hairpin Assembly Strategy with Luminescent Iridium Complexes

Pneumonia is a prevalent acute respiratory infection and a major cause of mortality and hospitalization, and the urgent demand for a rapid, direct, and highly accurate diagnostic method capable of detecting both <i>Streptococcus pneumoniae</i> (<i>S. pneumoniae</i>) and <i>Klebsiella pneumoniae</i> (<i>K. pneumoniae</i>) arises from their prominent roles as the primary pathogens responsible for pneumonia. Herein, two luminescent iridium complexes with nonoverlapping photoluminescence spectra, iridium(III)-bis [4,6-(difluorophenyl)-pyridinato-N,C<sup>2</sup>'] picolinate (abbreviated as Ir-B) and bis (2-(3,5- dimethylphenyl) quinoline-C2,N') (acetylacetonato) iridium(III)) (abbreviated as Ir-R), were unprecedently proposed to construct a novel wavelength-resolved magnetic multiplex biosensor for simultaneous detection of <i>S. pneumoniae</i> and <i>K. pneumoniae</i> based on catalytic hairpin assembly (CHA) signal amplification strategy combined with dye-doped silica nanoparticles. Notably, the proposed wavelength-resolved multiplex biosensor not only exhibits a broad linear range from 50 pM to 10 nM but also demonstrates excellent recovery rates for <i>S. pneumoniae</i> (96.1-99.3%) and <i>K. pneumoniae</i> (94.8-101.5%) in real clinical samples, with corresponding relative standard deviation (RSD) values ranging from 2.57 to 3.15% for <i>S. pneumoniae</i> and 1.45 to 3.17% for <i>K. pneumoniae</i>. These favorable experimental outcomes undoubtedly offer a promising approach for the simultaneous detection of multiple pathogens in the future.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-01-09
DOI
https://doi.org/10.1021/acs.analchem.4c06318
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wavelength-Resolved Magnetic Multiplex Biosensor for Simultaneous and Ultrasensitive Detection of Pneumonia Pathogens via Catalytic Hairpin Assembly Strategy with Luminescent Iridium Complexes

Libing Ke, Yaoyao Xu, Yuyang Zhou, Chenji Dai
2 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
1.61
article

Wavelength-Resolved Magnetic Multiplex Biosensor for Simultaneous and Ultrasensitive Detection of Pneumonia Pathogens via Catalytic Hairpin Assembly Strategy with Luminescent Iridium Complexes

Libing Ke, Yaoyao Xu, Yuyang Zhou, Chenji Dai
article en
2 citations

Abstract

Pneumonia is a prevalent acute respiratory infection and a major cause of mortality and hospitalization, and the urgent demand for a rapid, direct, and highly accurate diagnostic method capable of detecting both <i>Streptococcus pneumoniae</i> (<i>S. pneumoniae</i>) and <i>Klebsiella pneumoniae</i> (<i>K. pneumoniae</i>) arises from their prominent roles as the primary pathogens responsible for pneumonia. Herein, two luminescent iridium complexes with nonoverlapping photoluminescence spectra, iridium(III)-bis [4,6-(difluorophenyl)-pyridinato-N,C<sup>2</sup>'] picolinate (abbreviated as Ir-B) and bis (2-(3,5- dimethylphenyl) quinoline-C2,N') (acetylacetonato) iridium(III)) (abbreviated as Ir-R), were unprecedently proposed to construct a novel wavelength-resolved magnetic multiplex biosensor for simultaneous detection of <i>S. pneumoniae</i> and <i>K. pneumoniae</i> based on catalytic hairpin assembly (CHA) signal amplification strategy combined with dye-doped silica nanoparticles. Notably, the proposed wavelength-resolved multiplex biosensor not only exhibits a broad linear range from 50 pM to 10 nM but also demonstrates excellent recovery rates for <i>S. pneumoniae</i> (96.1-99.3%) and <i>K. pneumoniae</i> (94.8-101.5%) in real clinical samples, with corresponding relative standard deviation (RSD) values ranging from 2.57 to 3.15% for <i>S. pneumoniae</i> and 1.45 to 3.17% for <i>K. pneumoniae</i>. These favorable experimental outcomes undoubtedly offer a promising approach for the simultaneous detection of multiple pathogens in the future.

Analytical ChemistryVol. 97(2)
Suzhou University of Science and Technology (CN)
Joint Project of Industry-University-Research of Jiangsu Province
Openalex Percentile: Top 20%
Advanced biosensing and bioanalysis techniques
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wavelength-Resolved Magnetic Multiplex Biosensor for Simultaneous and Ultrasensitive Detection of Pneumonia Pathogens via Catalytic Hairpin Assembly Strategy with Luminescent Iridium Complexes — Libing Ke, Yaoyao Xu, et al. · Analytical Chemistry (2025) | TGRS Research Map | TGRS