Radio Frequency-Based Vascular Dementia Sensing and Imaging System Targeting Smart Glasses

Vascular dementia is the second most prevalent type of dementia among the elderly population and is one of the leading causes of mortality. Ischemic stroke and brain atrophy are the predominant pathologies associated with vascular dementia. Early detection and regular monitoring are crucial to prevent the advancement of vascular dementia. Conventional medical imaging is expensive, requires extensive medical supervision and is not easily accessible. This research presents a novel concept of low-cost and non-invasive smart glasses, equipped with miniaturized octagonal monopole-patch antenna (OMPA) sensors and a crescent array sensor for vascular dementia detection. This Radio Frequency (RF) enabled portable system is capable of accurately identifying and imaging brain infarction, atrophy and stroke in their early stages. The fabricated device is experimentally verified using multiple artificial stroke and atrophy targets inside a realistic brain phantom. The backscattered RF data is iteratively processed using customized imaging algorithms to achieve improved image quality, noise suppression, and contrast resolution with reduced image artifacts and computational complexity. Based on the iterative refinement, the Double Stage Minimum Variance Delay Multiply and Sum (DS-MV-DMAS) algorithm is proposed for imaging stroke and brain atrophy. The quantitative results indicate that DS-MV-DMAS results in 43% lower level of side lobes and leads to 26%, 28% and 27% improvement in signal-to-noise ratio, full width at half-maximum and contrast ratio, respectively, compared to other state-of-the-art imaging algorithms. The promising results demonstrate the feasibility of the prototype system as a cost-effective, portable and non-invasive alternative for the diagnosis and monitoring of vascular dementia.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-01-09
DOI
https://doi.org/10.1109/jsen.2024.3525441
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radio Frequency-Based Vascular Dementia Sensing and Imaging System Targeting Smart Glasses

Usman Anwar, Peter Lomax, Tughrul Arslan, Tom C. Russ
2 links
IEEE Sensors Journal
Optical Imaging and Spectroscopy Techniques
article

Radio Frequency-Based Vascular Dementia Sensing and Imaging System Targeting Smart Glasses

Usman Anwar, Peter Lomax, Tughrul Arslan, Tom C. Russ
article en

Abstract

Vascular dementia is the second most prevalent type of dementia among the elderly population and is one of the leading causes of mortality. Ischemic stroke and brain atrophy are the predominant pathologies associated with vascular dementia. Early detection and regular monitoring are crucial to prevent the advancement of vascular dementia. Conventional medical imaging is expensive, requires extensive medical supervision and is not easily accessible. This research presents a novel concept of low-cost and non-invasive smart glasses, equipped with miniaturized octagonal monopole-patch antenna (OMPA) sensors and a crescent array sensor for vascular dementia detection. This Radio Frequency (RF) enabled portable system is capable of accurately identifying and imaging brain infarction, atrophy and stroke in their early stages. The fabricated device is experimentally verified using multiple artificial stroke and atrophy targets inside a realistic brain phantom. The backscattered RF data is iteratively processed using customized imaging algorithms to achieve improved image quality, noise suppression, and contrast resolution with reduced image artifacts and computational complexity. Based on the iterative refinement, the Double Stage Minimum Variance Delay Multiply and Sum (DS-MV-DMAS) algorithm is proposed for imaging stroke and brain atrophy. The quantitative results indicate that DS-MV-DMAS results in 43% lower level of side lobes and leads to 26%, 28% and 27% improvement in signal-to-noise ratio, full width at half-maximum and contrast ratio, respectively, compared to other state-of-the-art imaging algorithms. The promising results demonstrate the feasibility of the prototype system as a cost-effective, portable and non-invasive alternative for the diagnosis and monitoring of vascular dementia.

IEEE Sensors JournalVol. 25(4)
Alzheimer Scotland (GB), University of Edinburgh (GB)
Higher Education Commision, Pakistan, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 99%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.