Evaluation of point-of-care haemoglobin measurement accuracy in surgery (PREMISE) and implications for transfusion practice: a prospective cohort study

No point-of-care Hgb device demonstrated limits of agreement that were smaller than the agreement difference of 4 g L<sup>-1</sup>. Despite this, HemoCue can be safely used to inform transfusion decisions in surgery, given its error probability of <4% in transfusion scenarios.

Authors

Institutions

Publication Details

Journal
British Journal of Anaesthesia
Published
2025-01-09
DOI
https://doi.org/10.1016/j.bja.2024.09.033
Citations
2
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
1.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of point-of-care haemoglobin measurement accuracy in surgery (PREMISE) and implications for transfusion practice: a prospective cohort study

Ranjeeta Mallick, Tim Ramsay, Julie Hallet, François Martin Carrier et al.
2 citations
British Journal of Anaesthesia
Blood transfusion and management
1.55
article

Evaluation of point-of-care haemoglobin measurement accuracy in surgery (PREMISE) and implications for transfusion practice: a prospective cohort study

Ranjeeta Mallick, Tim Ramsay, Julie Hallet, François Martin Carrier, Julie Shaw, Karine Brousseau, Christopher Wherrett, Justin Presseau, Daniel I. McIsaac, Guillaume Martel, Dean Fergusson, Leah Monette, Alan Tinmouth, Aklile Workneh
article en
2 citations

Abstract

No point-of-care Hgb device demonstrated limits of agreement that were smaller than the agreement difference of 4 g L<sup>-1</sup>. Despite this, HemoCue can be safely used to inform transfusion decisions in surgery, given its error probability of <4% in transfusion scenarios.

British Journal of AnaesthesiaVol. 134(2)
Sunnybrook Health Science Centre (CA), Ottawa Hospital (CA), Health Sciences Centre (CA), Canadian Electricity Association (CA), Centre Hospitalier de l’Université de Montréal (CA), Ottawa Hospital Research Institute (CA), Sunnybrook Research Institute
Canadian Blood Services
Openalex Percentile: Top 21%
Blood transfusion and management
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.