Establishment of Diagnostic Reference Levels for Childhood Head CT in the District of Abidjan in Côte d’Ivoire

Computed tomography is an indispensable X-ray imaging modality used to diagnose numerous pathologies, but it can also involve the delivery of high ionizing radiation doses harmful to the health of patients. This study aims to survey the level of radiation doses delivered to child patients during head exams in CT imaging to set up the Dosimetric Reference Levels (DRLs), a routine dose optimization tool, based on data acquired at the University Hospital of Angré (UHA), the University Hospital of Treichville (UHT) and the Polyclinic Hospital Farah (Farah) for optimizing procedures in Ivorian hospitals. Prospectively performed on 334 CT images of 186 child patients, this study was carried out on CT systems such as Hitachi Scenaria, Sinovision Insitum, and Philips Incisive used respectively at UHA, UHT and Farah. Children’s scan data were classified into four age bands: vol or dose-length product as DLP) value, whatever the hospital, increases with respect to the age of child patients. Based on the 75th percentile of the whole dose distributions, the DRLs of the CTDIvol is 54.37 mGy whatever the age groups and those of the DLP with respect to age bands are 1224.55 mGy∙cm, 1414.06 mGy∙cm, 1632.24 mGy.cm and 1544.57 mGy∙cm, respectively. The averaged values of CTDIvol and DLP smaller than the corresponding DRLs values suggest that practices in our three facilities are optimized. However, comparing our results with those from different international studies, we see that the CTDIvol and DLP values obtained in the present work are higher. These results suggest additional surveys to ensure our DRLs values and efforts from radiologists, imaging technicians and medical physicists to strengthen clinical procedures for the radiation protection of children undergoing CT scans in Côte d’Ivoire.

Authors

Publication Details

Journal
World Journal of Nuclear Science and Technology
Published
2025-01-01
DOI
https://doi.org/10.4236/wjnst.2025.151004
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of Diagnostic Reference Levels for Childhood Head CT in the District of Abidjan in Côte d’Ivoire

Aboubakar Sidiki Diabaté, Koutoua Joseph Anouan, Raïssa-Michelle Kabas, Jean-Paul Kouao
World Journal of Nuclear Science and Technology
Radiation Dose and Imaging
article

Establishment of Diagnostic Reference Levels for Childhood Head CT in the District of Abidjan in Côte d’Ivoire

Aboubakar Sidiki Diabaté, Koutoua Joseph Anouan, Raïssa-Michelle Kabas, Jean-Paul Kouao
article en

Abstract

Computed tomography is an indispensable X-ray imaging modality used to diagnose numerous pathologies, but it can also involve the delivery of high ionizing radiation doses harmful to the health of patients. This study aims to survey the level of radiation doses delivered to child patients during head exams in CT imaging to set up the Dosimetric Reference Levels (DRLs), a routine dose optimization tool, based on data acquired at the University Hospital of Angré (UHA), the University Hospital of Treichville (UHT) and the Polyclinic Hospital Farah (Farah) for optimizing procedures in Ivorian hospitals. Prospectively performed on 334 CT images of 186 child patients, this study was carried out on CT systems such as Hitachi Scenaria, Sinovision Insitum, and Philips Incisive used respectively at UHA, UHT and Farah. Children’s scan data were classified into four age bands: vol or dose-length product as DLP) value, whatever the hospital, increases with respect to the age of child patients. Based on the 75th percentile of the whole dose distributions, the DRLs of the CTDIvol is 54.37 mGy whatever the age groups and those of the DLP with respect to age bands are 1224.55 mGy∙cm, 1414.06 mGy∙cm, 1632.24 mGy.cm and 1544.57 mGy∙cm, respectively. The averaged values of CTDIvol and DLP smaller than the corresponding DRLs values suggest that practices in our three facilities are optimized. However, comparing our results with those from different international studies, we see that the CTDIvol and DLP values obtained in the present work are higher. These results suggest additional surveys to ensure our DRLs values and efforts from radiologists, imaging technicians and medical physicists to strengthen clinical procedures for the radiation protection of children undergoing CT scans in Côte d’Ivoire.

World Journal of Nuclear Science and TechnologyVol. 15(01)
Openalex Percentile: Top 99%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.