Novel primary standard for dynamic pressure up to 500 MPa

Dynamic pressure measurements at high pressures, up to 500 MPa, are relevant for testing the performance and safety of ammunition, explosives, and weapons. Current primary standards for realizing dynamic pressure are laborious to use, making them impractical for daily calibration work. Consequently, industry still calibrates sensors using static methods, which can result in errors up to 10 %. A new design of a drop-weight device was developed by VTT MIKES, the National Metrology Institute of Finland, to overcome these issues. Based on this novel design, a high-pressure primary standard up to 500 MPa was developed for GUM, the National Metrology Institute of Poland. In this paper, the design principles and initial test results are presented together with a preliminary uncertainty budget. Based on this study, an uncertainty level of 0.9 % ( k = 2) is achieved, which is a significant improvement compared to current state-of-the-art of around 2 %.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2025-01-09
DOI
https://doi.org/10.1016/j.measen.2024.101686
Citations
1
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
1.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel primary standard for dynamic pressure up to 500 MPa

Richard Högström, Antti Lakka, Jussi Hämäläinen, Leevi Salonen et al.
1 citations
Measurement Sensors
Scientific Measurement and Uncertainty Evaluation
1.40
article

Novel primary standard for dynamic pressure up to 500 MPa

Richard Högström, Antti Lakka, Jussi Hämäläinen, Leevi Salonen, Adam Brzozowski
article en
1 citations

Abstract

Dynamic pressure measurements at high pressures, up to 500 MPa, are relevant for testing the performance and safety of ammunition, explosives, and weapons. Current primary standards for realizing dynamic pressure are laborious to use, making them impractical for daily calibration work. Consequently, industry still calibrates sensors using static methods, which can result in errors up to 10 %. A new design of a drop-weight device was developed by VTT MIKES, the National Metrology Institute of Finland, to overcome these issues. Based on this novel design, a high-pressure primary standard up to 500 MPa was developed for GUM, the National Metrology Institute of Poland. In this paper, the design principles and initial test results are presented together with a preliminary uncertainty budget. Based on this study, an uncertainty level of 0.9 % ( k = 2) is achieved, which is a significant improvement compared to current state-of-the-art of around 2 %.

Measurement SensorsVol. 38
Central Office of Measures (PL), VTT Technical Research Centre of Finland (FI)
Affordable and clean energy
Openalex Percentile: Top 20%
Scientific Measurement and Uncertainty Evaluation
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.