Physics-Informed Autoencoder for DSC-MRI Perfusion Post-Processing: Application to Glioma Grading

DSC-MRI perfusion is a medical imaging technique for diagnosing and prognosing brain tumors and strokes. Its analysis relies on mathematical deconvolution, but noise or motion artifacts in a clinical environment can disrupt this process, leading to incorrect estimates of perfusion parameters. Although deep learning approaches have shown promising results, their calibrations typically rely on third-party deconvolution algorithms to generate reference outputs and are bound to reproduce their limitations. To address this problem, we propose a physics-informed autoencoder that uses an analytical model to decode the perfusion parameters and guide the learning of the encoding network. This autoencoder is trained in a self-supervised fashion without any third-party software and its performance is evaluated on a database with glioma patients. Our method shows reliable results for glioma grading in accordance with other well-known deconvolution algorithms despite a lower computation time. It also achieved competitive performance even in the presence of high noise, which is critical in a medical environment.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10980699
Primary Topic
Brain Tumor Detection and Classification
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physics-Informed Autoencoder for DSC-MRI Perfusion Post-Processing: Application to Glioma Grading

Mathieu Naudin, David Helbert, Alexandre Bône, Noëlie Debs et al.
Brain Tumor Detection and Classification
article

Physics-Informed Autoencoder for DSC-MRI Perfusion Post-Processing: Application to Glioma Grading

Mathieu Naudin, David Helbert, Alexandre Bône, Noëlie Debs, Pierre Fayolle, Rémy Guillevin, Pascal Bourdon
article en

Abstract

DSC-MRI perfusion is a medical imaging technique for diagnosing and prognosing brain tumors and strokes. Its analysis relies on mathematical deconvolution, but noise or motion artifacts in a clinical environment can disrupt this process, leading to incorrect estimates of perfusion parameters. Although deep learning approaches have shown promising results, their calibrations typically rely on third-party deconvolution algorithms to generate reference outputs and are bound to reproduce their limitations. To address this problem, we propose a physics-informed autoencoder that uses an analytical model to decode the perfusion parameters and guide the learning of the encoding network. This autoencoder is trained in a self-supervised fashion without any third-party software and its performance is evaluated on a database with glioma patients. Our method shows reliable results for glioma grading in accordance with other well-known deconvolution algorithms despite a lower computation time. It also achieved competitive performance even in the presence of high noise, which is critical in a medical environment.

Guerbet (France) (FR), Université de Poitiers (FR), XLIM (FR), Centre Hospitalier Universitaire de Poitiers (FR), Imagerie par Résonance Magnétique Médicale et Multi-Modalités (FR), Laboratoire de Mathématiques et Applications (FR)
Association Nationale de la Recherche et de la Technologie
Openalex Percentile: Top 99%
Brain Tumor Detection and Classification
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Physics-Informed Autoencoder for DSC-MRI Perfusion Post-Processing: Application to Glioma Grading — Mathieu Naudin, David Helbert, et al. · (2025) | TGRS Research Map | TGRS