Thermal assessment of Li-ion battery cells and coolant in hybrid electric vehicles system: Application of conjugate condition and response surface methodology

Numerical and response surface (RS) analysis of the thermal performance of prismatic battery-operated cell is performed cooled by the forced flow of air considering conjugate condition at the cell-fluid interface. At the battery-air interface, where the heat flow continuity and temperature condition exist, the combined heat transfer condition is examined. Control volume-based code is developed where the Navier-stokes equation is solved by SIMPLE algorithm. The numerical work is endorsed by the experimental work specified in the literature. The effects of ζ cc (conduction–convection parameter – 0.06 to 0.1), Ar (Aspect ratio 10 to 30), volumetric heat generation ( – 0.1 to 1.0), and Re (Reynolds number – 250 to 2000) are investigated. The effect of the parameters mentioned above on temperature distribution (TeDi) along the axial direction (AD) in the battery cell (BC) and transverse TeDi in the fluid channel is investigated. The variations in temperature gradient and maximum temperature (MT) difference for different , ζ cc , Re , and Ar are illustrated. The RS methodology is employed to analyze the MT of the battery. The MT difference obtained with increasing and R e is quite significant. The MT difference obtained with an increase in ζ cc and Re is much less and the same is negligible with Ar . Re below 500 and ζ cc below 0.06 will cause a greater increase in MT, which acts as lower limits. Similarly, Re above 1250 and ζ cc above 0.08 do not help in the reduction of MT. For = 0.7 and above , the temperature crosses its maximum permissible limit of the battery cell. The RS model developed gives an accuracy of 97%, close to the numerical values. The RS analysis of MT indicates that is the most influential parameter.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-01-10
DOI
https://doi.org/10.1016/j.csite.2025.105766
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal assessment of Li-ion battery cells and coolant in hybrid electric vehicles system: Application of conjugate condition and response surface methodology

Sung Goon Park, Asif Afzal, Ravindra Jilte, Mamdooh Alwetaishi et al.
Case Studies in Thermal Engineering
Advanced Battery Technologies Research
article

Thermal assessment of Li-ion battery cells and coolant in hybrid electric vehicles system: Application of conjugate condition and response surface methodology

Sung Goon Park, Asif Afzal, Ravindra Jilte, Mamdooh Alwetaishi, Ramis MK, Ümit Ağbulut, Qasem M. Al‐Mdallal, Abdulrajak Buradi
article en

Abstract

Numerical and response surface (RS) analysis of the thermal performance of prismatic battery-operated cell is performed cooled by the forced flow of air considering conjugate condition at the cell-fluid interface. At the battery-air interface, where the heat flow continuity and temperature condition exist, the combined heat transfer condition is examined. Control volume-based code is developed where the Navier-stokes equation is solved by SIMPLE algorithm. The numerical work is endorsed by the experimental work specified in the literature. The effects of ζ cc (conduction–convection parameter – 0.06 to 0.1), Ar (Aspect ratio 10 to 30), volumetric heat generation ( – 0.1 to 1.0), and Re (Reynolds number – 250 to 2000) are investigated. The effect of the parameters mentioned above on temperature distribution (TeDi) along the axial direction (AD) in the battery cell (BC) and transverse TeDi in the fluid channel is investigated. The variations in temperature gradient and maximum temperature (MT) difference for different , ζ cc , Re , and Ar are illustrated. The RS methodology is employed to analyze the MT of the battery. The MT difference obtained with increasing and R e is quite significant. The MT difference obtained with an increase in ζ cc and Re is much less and the same is negligible with Ar . Re below 500 and ζ cc below 0.06 will cause a greater increase in MT, which acts as lower limits. Similarly, Re above 1250 and ζ cc above 0.08 do not help in the reduction of MT. For = 0.7 and above , the temperature crosses its maximum permissible limit of the battery cell. The RS model developed gives an accuracy of 97%, close to the numerical values. The RS analysis of MT indicates that is the most influential parameter.

Case Studies in Thermal EngineeringVol. 66
Chandigarh University (IN), Seoul National University of Science and Technology (KR), Taif University (SA), United Arab Emirates University (AE), Yıldız Technical University (TR), Centre for Research and Development (ZW), Visvesvaraya Technological University (IN), Maulana Azad National Institute of Technology (IN)
Affordable and clean energy
Openalex Percentile: Top 100%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.