Accessible halitosis diagnosis: validating the accuracy of novel AI-based compact VSC measuring instrument

Halitosis presents a significant global health concern, necessitating the development of precise and efficient testing methodologies owing to the high prevalence and the associated social and psychological effects. The measurement of volatile sulfur compounds (VSCs), recognized as primary contributors to halitosis, is particularly significant. While gas chromatography (GC-MS) offers accurate measurements, its bulky and expensive nature limits widespread accessibility. Hence, this study endeavors to devise a compact yet highly accurate AI-based halitosis measurement apparatus, termed 'Kunkun dental' and validate its efficacy. Specifically, we intend to compare the VSC concentrations obtained from halitosis patients' breath samples using Kunkun dental against those from conventional GC-MS to assess the criterion validity of the new testing method. The study cohort comprised 68 halitosis patients aged 20 years or older, attending the breath freshening outpatient clinic at Tokyo Medical and Dental University Hospital between October 2022 and March 2023, who consented to participate and underwent routine measurements. Participants completed an age and sex questionnaire, while VSC concentrations were determined using both GC-MS and Kunkun dental (H<sub>2</sub>S, CH<sub>3</sub>SH, (CH<sub>3</sub>)<sub>2</sub>S), enabling a comparative analysis of the results. Pearson product-moment correlation coefficients between GC-MS and Kunkun dental indicated significant correlations for all three gases: 0.719 for H<sub>2</sub>S, 0.821 for CH<sub>3</sub>SH, and 0.637 for (CH<sub>3</sub>)<sub>2</sub>S. Moreover, sensitivity and specificity in accordance with the predefined thresholds were confirmed, and their values ranged from 0.59 to 0.86 and 0.53-0.77, respectively. Furthermore, grouping Kunkun dental measurements into low-, medium-, and high-concentration groups revealed significantly higher GC-MS VSC concentrations in samples with elevated Kunkun dental readings. The amalgamation of AI technology and a semiconductor gas sensor holds great promise in creating a compact and precise halitosis analyzer. This study underscores the feasibility and effectiveness of Kunkun dental as a reliable tool for halitosis assessment, affirming its utility in clinical practice.

Authors

Institutions

Publication Details

Journal
Journal of Breath Research
Published
2025-01-09
DOI
https://doi.org/10.1088/1752-7163/ada84e
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accessible halitosis diagnosis: validating the accuracy of novel AI-based compact VSC measuring instrument

Sakae Enomoto, Jun Aida, Takashi Zaitsu, Hiroshi Akiyama et al.
Journal of Breath Research
Advanced Chemical Sensor Technologies
article

Accessible halitosis diagnosis: validating the accuracy of novel AI-based compact VSC measuring instrument

Sakae Enomoto, Jun Aida, Takashi Zaitsu, Hiroshi Akiyama, Risa Aritomi
article en

Abstract

Halitosis presents a significant global health concern, necessitating the development of precise and efficient testing methodologies owing to the high prevalence and the associated social and psychological effects. The measurement of volatile sulfur compounds (VSCs), recognized as primary contributors to halitosis, is particularly significant. While gas chromatography (GC-MS) offers accurate measurements, its bulky and expensive nature limits widespread accessibility. Hence, this study endeavors to devise a compact yet highly accurate AI-based halitosis measurement apparatus, termed 'Kunkun dental' and validate its efficacy. Specifically, we intend to compare the VSC concentrations obtained from halitosis patients' breath samples using Kunkun dental against those from conventional GC-MS to assess the criterion validity of the new testing method. The study cohort comprised 68 halitosis patients aged 20 years or older, attending the breath freshening outpatient clinic at Tokyo Medical and Dental University Hospital between October 2022 and March 2023, who consented to participate and underwent routine measurements. Participants completed an age and sex questionnaire, while VSC concentrations were determined using both GC-MS and Kunkun dental (H<sub>2</sub>S, CH<sub>3</sub>SH, (CH<sub>3</sub>)<sub>2</sub>S), enabling a comparative analysis of the results. Pearson product-moment correlation coefficients between GC-MS and Kunkun dental indicated significant correlations for all three gases: 0.719 for H<sub>2</sub>S, 0.821 for CH<sub>3</sub>SH, and 0.637 for (CH<sub>3</sub>)<sub>2</sub>S. Moreover, sensitivity and specificity in accordance with the predefined thresholds were confirmed, and their values ranged from 0.59 to 0.86 and 0.53-0.77, respectively. Furthermore, grouping Kunkun dental measurements into low-, medium-, and high-concentration groups revealed significantly higher GC-MS VSC concentrations in samples with elevated Kunkun dental readings. The amalgamation of AI technology and a semiconductor gas sensor holds great promise in creating a compact and precise halitosis analyzer. This study underscores the feasibility and effectiveness of Kunkun dental as a reliable tool for halitosis assessment, affirming its utility in clinical practice.

Journal of Breath ResearchVol. 19(2)
Tokyo Medical and Dental University (JP), Konica Minolta (Japan) (JP)
Quality Education
Openalex Percentile: Top 100%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.