Real-Time Monitoring of Electrode Surface Changes in Fast-Scan Cyclic Voltammetry Using Fourier Transform Electrochemical Impedance Spectroscopy

Fast-scan cyclic voltammetry (FSCV) is a widely used electrochemical technique to measure the phasic response of neurotransmitters in the brain. It has the advantage of reducing tissue damage to the brain due to the use of carbon fiber microelectrodes as well as having a high temporal resolution (10 Hz) sufficient to monitor neurotransmitter release in vivo. During the FSCV experiment, the surface of the carbon fiber microelectrode is inevitably changed by the fouling effect. In terms of redox peak potential and sensitivity against neurotransmitters, a changed electrode surface results in a voltammogram that differs from the precalibration. However, when an electrode is implanted in the brain, the method for monitoring the electrode status change is limited. In this study, we propose employing an electrochemical impedance concept to monitor the gradual change of the electrode surface during FSCV scanning. Fourier transform electrochemical impedance spectroscopy (FTEIS) was used in combination with FSCV to detect the real-time impedance of the electrode. The relationship between impedance and electrode surface conditions was studied by immersing carbon fiber microelectrodes in bovine serum albumin solution to induce biofouling and diminish electrode sensitivity. As a result of the nonspecific adsorption of bovine serum albumin during the interleave scan of FSCV and FTEIS, both the measured dopamine response and the capacitance of the equivalent circuit model from FTEIS decreased over time. The capacitance and sensitivity of the electrode showed correlation (R<sup>2</sup> = 0.90), while the resistance of the equivalent circuit did not. In vivo measurements using the interleave scan of FSCV and FTEIS were also carried out to observe biofouling on the FSCV electrode surface and to measure dopamine sensitivity in the striatum of the rat brain for an hour. The results showed that the resistance did not significantly change, while capacitance and measured dopamine were significantly diminishing over time. In summary, real-time neurotransmitter measurements and electrode monitoring with the combination of FSCV and FTEIS would be useful in neuroscience research.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-01-09
DOI
https://doi.org/10.1021/acsomega.4c08240
Citations
5
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
2.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Monitoring of Electrode Surface Changes in Fast-Scan Cyclic Voltammetry Using Fourier Transform Electrochemical Impedance Spectroscopy

Dong Pyo Jang, Cheonho Park, Sangmun Hwang, Yoonbae Oh et al.
5 citations
ACS Omega
Electrochemical Analysis and Applications
2.58
article

Real-Time Monitoring of Electrode Surface Changes in Fast-Scan Cyclic Voltammetry Using Fourier Transform Electrochemical Impedance Spectroscopy

Dong Pyo Jang, Cheonho Park, Sangmun Hwang, Yoonbae Oh, Youngjong Kwak, Hojin Shin, Jaehyun Jang, Kendall H. Lee, Se Jin Jeon, Hyun U. Cho
article en
5 citations

Abstract

Fast-scan cyclic voltammetry (FSCV) is a widely used electrochemical technique to measure the phasic response of neurotransmitters in the brain. It has the advantage of reducing tissue damage to the brain due to the use of carbon fiber microelectrodes as well as having a high temporal resolution (10 Hz) sufficient to monitor neurotransmitter release in vivo. During the FSCV experiment, the surface of the carbon fiber microelectrode is inevitably changed by the fouling effect. In terms of redox peak potential and sensitivity against neurotransmitters, a changed electrode surface results in a voltammogram that differs from the precalibration. However, when an electrode is implanted in the brain, the method for monitoring the electrode status change is limited. In this study, we propose employing an electrochemical impedance concept to monitor the gradual change of the electrode surface during FSCV scanning. Fourier transform electrochemical impedance spectroscopy (FTEIS) was used in combination with FSCV to detect the real-time impedance of the electrode. The relationship between impedance and electrode surface conditions was studied by immersing carbon fiber microelectrodes in bovine serum albumin solution to induce biofouling and diminish electrode sensitivity. As a result of the nonspecific adsorption of bovine serum albumin during the interleave scan of FSCV and FTEIS, both the measured dopamine response and the capacitance of the equivalent circuit model from FTEIS decreased over time. The capacitance and sensitivity of the electrode showed correlation (R<sup>2</sup> = 0.90), while the resistance of the equivalent circuit did not. In vivo measurements using the interleave scan of FSCV and FTEIS were also carried out to observe biofouling on the FSCV electrode surface and to measure dopamine sensitivity in the striatum of the rat brain for an hour. The results showed that the resistance did not significantly change, while capacitance and measured dopamine were significantly diminishing over time. In summary, real-time neurotransmitter measurements and electrode monitoring with the combination of FSCV and FTEIS would be useful in neuroscience research.

ACS OmegaVol. 10(2)
Mayo Clinic (US), Hallym University (KR), Korea University (KR), Hanyang University (KR), University of Virginia (US)
Korea Health Industry Development Institute, National Research Foundation of Korea, National Institute of Neurological Disorders and Stroke
Affordable and clean energy
Openalex Percentile: Top 12%
Electrochemical Analysis and Applications
2.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.