Degradation Classification of Low-Voltage Zinc Oxide Varistors Using K-NN Algorithm

In this paper, the degradation of low voltage varistors-based arrestors exposed to slow-front overvoltage surges is analyzed. MOV samples are degraded under different set number of surges. The reference voltages of varistor samples are measured before and after the application of switching surges. The KNN algorithm is then applied to analyze the percentage change in reference voltage values and classify the degradation condition. Additionally, the ANOVA statistical test is used to determine the correlation between the number of surges and the percentage change in reference voltages. The KNN classification accuracy is reported to be 96.4%, with precision and recall values of 96.9% and 96.4% respectively. The F-1 score is calculated to be 96.4%. Results indicate that the KNN algorithm effectively classifies the degradation condition of the MOVs. In contrast, the ANOVA results show that there is a significant mean reference voltage difference observed between the groups of varistors that were exposed to different sets of switching surges. This suggests that the number of switching surges applied has a notable effect on the reference voltage values of the varistors.

Authors

Institutions

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.1109/powerafrica61624.2024.10759505
Citations
1
Primary Topic
Industrial Vision Systems and Defect Detection
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Degradation Classification of Low-Voltage Zinc Oxide Varistors Using K-NN Algorithm

Lutendo Muremi, Pitshou Ntambu Bokoro
1 citations
Industrial Vision Systems and Defect Detection
0.35
article

Degradation Classification of Low-Voltage Zinc Oxide Varistors Using K-NN Algorithm

Lutendo Muremi, Pitshou Ntambu Bokoro
article en
1 citations

Abstract

In this paper, the degradation of low voltage varistors-based arrestors exposed to slow-front overvoltage surges is analyzed. MOV samples are degraded under different set number of surges. The reference voltages of varistor samples are measured before and after the application of switching surges. The KNN algorithm is then applied to analyze the percentage change in reference voltage values and classify the degradation condition. Additionally, the ANOVA statistical test is used to determine the correlation between the number of surges and the percentage change in reference voltages. The KNN classification accuracy is reported to be 96.4%, with precision and recall values of 96.9% and 96.4% respectively. The F-1 score is calculated to be 96.4%. Results indicate that the KNN algorithm effectively classifies the degradation condition of the MOVs. In contrast, the ANOVA results show that there is a significant mean reference voltage difference observed between the groups of varistors that were exposed to different sets of switching surges. This suggests that the number of switching surges applied has a notable effect on the reference voltage values of the varistors.

University of Johannesburg (ZA)
Openalex Percentile: Top 32%
Industrial Vision Systems and Defect Detection
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Degradation Classification of Low-Voltage Zinc Oxide Varistors Using K-NN Algorithm — Lutendo Muremi, Pitshou Ntambu Bokoro · (2024) | TGRS Research Map | TGRS