Performance assessment of novel chemiluminescence immunoassays for the detection of specific biomarkers for Alzheimer’s disease

Abstract Background To support diagnosis of Alzheimer’s disease (AD), concentrations of Aβ 1‐42 , tTau and pTau(181) and the Aβ 1‐42 /Aβ 1‐40 ratio are determined in cerebrospinal fluid (CSF). To increase standardization and comparability between diagnostic laboratories, certified reference material (CRM) is used to evaluate the trueness of novel assays. Due to lack of CRMs for tTau, pTau(181), and Aβ 1‐40 , comparability may be assessed by comparing assays from different manufacturers. This study compares the performance of novel chemiluminescence immunoassays (ChLIAs) developed by EUROIMMUN with established chemiluminescence assays. Method Biomarker concentrations were determined in 110 CSF samples (patients without known diagnosis; mean age 57.2 years, range 11–94 years; 49 female, 60 male, 1 unknown) using the Beta‐Amyloid (1‐42), Beta‐Amyloid (1‐40), Total‐Tau and pTau(181) ChLIAs (all EUROIMMUN) and the corresponding Lumipulse G assays (Fujirebio). The assays were performed according to the manufacturers’ instructions on the fully automated random‐access devices IDS‐i10 (Immunodiagnostic Systems) and LUMIPULSE G 600II analyzer (Fujirebio), respectively. Agreement of results obtained with the two chemiluminescence systems was calculated. Result Overall agreement ranged from 89.0% to 97.3%. Agreement for the determination of normal biomarker concentrations was 93.4%–100% and 57.7%–94% for abnormal concentrations. The level of agreement was highest for Aβ 1‐42 determination. Pearson’s regression coefficient revealed high correlation of results (R=0.82 to R=0.99 for Aβ 1‐42 determination). While concentrations determined using EUROIMMUN assays were generally higher, numerical differences had minor influence on the diagnostic evaluation. Conclusion Using the EUROIMMUN ChLIAs, AD‐specific biomarkers can be measured with high precision and stability on fully automated random‐access devices. The highest level of agreement and correlation was found for Aβ 1‐42 determination as assays are aligned to the respective CRMs. This indicates the need to introduce CRMs for standardization of tTau, pTau(181), and Aβ 1‐40 assays.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.087324
Citations
1
Primary Topic
Alzheimer's disease research and treatments
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance assessment of novel chemiluminescence immunoassays for the detection of specific biomarkers for Alzheimer’s disease

Stefan Busse, Viola Borchardt, Philipp Arendt, Britta Brix et al.
1 citations
Alzheimer s & Dementia
Alzheimer's disease research and treatments
0.33
article

Performance assessment of novel chemiluminescence immunoassays for the detection of specific biomarkers for Alzheimer’s disease

Stefan Busse, Viola Borchardt, Philipp Arendt, Britta Brix, Mandy Busse, Katharina Römpler, A. Schulz, Stephanie Franco
article en
1 citations

Abstract

Abstract Background To support diagnosis of Alzheimer’s disease (AD), concentrations of Aβ 1‐42 , tTau and pTau(181) and the Aβ 1‐42 /Aβ 1‐40 ratio are determined in cerebrospinal fluid (CSF). To increase standardization and comparability between diagnostic laboratories, certified reference material (CRM) is used to evaluate the trueness of novel assays. Due to lack of CRMs for tTau, pTau(181), and Aβ 1‐40 , comparability may be assessed by comparing assays from different manufacturers. This study compares the performance of novel chemiluminescence immunoassays (ChLIAs) developed by EUROIMMUN with established chemiluminescence assays. Method Biomarker concentrations were determined in 110 CSF samples (patients without known diagnosis; mean age 57.2 years, range 11–94 years; 49 female, 60 male, 1 unknown) using the Beta‐Amyloid (1‐42), Beta‐Amyloid (1‐40), Total‐Tau and pTau(181) ChLIAs (all EUROIMMUN) and the corresponding Lumipulse G assays (Fujirebio). The assays were performed according to the manufacturers’ instructions on the fully automated random‐access devices IDS‐i10 (Immunodiagnostic Systems) and LUMIPULSE G 600II analyzer (Fujirebio), respectively. Agreement of results obtained with the two chemiluminescence systems was calculated. Result Overall agreement ranged from 89.0% to 97.3%. Agreement for the determination of normal biomarker concentrations was 93.4%–100% and 57.7%–94% for abnormal concentrations. The level of agreement was highest for Aβ 1‐42 determination. Pearson’s regression coefficient revealed high correlation of results (R=0.82 to R=0.99 for Aβ 1‐42 determination). While concentrations determined using EUROIMMUN assays were generally higher, numerical differences had minor influence on the diagnostic evaluation. Conclusion Using the EUROIMMUN ChLIAs, AD‐specific biomarkers can be measured with high precision and stability on fully automated random‐access devices. The highest level of agreement and correlation was found for Aβ 1‐42 determination as assays are aligned to the respective CRMs. This indicates the need to introduce CRMs for standardization of tTau, pTau(181), and Aβ 1‐40 assays.

Alzheimer s & DementiaVol. 20(S2)
Euroimmun Medizinische Labordiagnostika (Germany) (DE), University Hospital Magdeburg (DE)
Good health and well-being
Openalex Percentile: Top 34%
Alzheimer's disease research and treatments
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.