Non‐invasive quantification of [<sup>18</sup>F]‐PI‐2620 binding to tau deposits in the brain using an image‐derived input function

Abstract Background This study quantified tau binding in the brain with 18 F‐PI2620 PET using a non‐invasive Image‐Derived Input function(IDIF), derived using a new total‐body EXPLORER PET/CT scanner (Spencer et al.,2021). Additionally, we explored how PET scan duration influences the quantification of kinetic parameters across brain regions of interest(ROIs) that are vulnerable in Alzheimer’s Disease. Method The study cohort included 15 individuals (10 cognitively unimpaired, 3 mild cognitive impairment, and 2 AD; ages=68‐92 years; all tau negative) from the UC Davis ADRC. Dynamic total‐body 18 F‐PI‐2620 PET images were acquired over 90 minutes using the uEXPLORER (resolution=2.344 mm isotropic voxels, framing protocol:30×2s,12×10s,7×60s,16×300s). Brain cropped PET images were motion corrected (Jenkinson et al.,2002), and linearly registered to individual T1‐weighted(T1W) MRIs (Jenkinson &amp; Smith, 2001). Grey matter ROIs, including the medial temporal(MT), posterior cingulate(PC), and lateral parietal(LP) cortices, were obtained parcellating T1W images (Desikan et al.,2006). Dynamic time activity curves for each brain ROI were fitted to a reversible two‐tissue compartmental model(2TCM), accounting for delay, using a subject‐specific IDIF(plasma and metabolite‐corrected) derived from the descending aorta of the same images (Figure 1). ROI‐specific micro and macro kinetic parameters were estimated. Logan graphical analysis (Logan,2000) was also used to estimate total distribution volume(V T ). Result 2TCM with IDIF demonstrated high‐quality fits of 18 F‐PI2620 binding across grey matter ROIs (Figure 1). Perfusion (K 1 ) was observed to be reduced in MT compared to PC and LP (Figure 2A). All kinetic parameters remained relatively stable after the 60‐minute scan window across all ROIs. Notably, K 1 showed stability after 30 minutes of scan duration across all ROIs (Figure 2 and 3). A strong correlation was observed between VT estimated using 2TCM and Logan plot analysis, across all ROIs LP(r=1.00, p&lt;0.001), MT(r=0.96, p&lt;0.001), PC(r =1.00, p&lt;0.001). Additionally, significant negative correlation was observed between binding potential and perfusion across all ROIs (r=‐0.40, p=0.007). Conclusion This study highlights the utility of a non‐invasive descending aorta IDIF derived using a total‐body EXPLORER PET/CT scanner to quantify 18 F‐PI‐2620 grey matter kinetics. Preliminary findings suggest that a 60‐minute scan window may be sufficient for reliable quantification of kinetic parameters, while a 30‐minute scan time may suffice for perfusion alone. These findings warrant validation in a cohort involving tau positive individuals.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.088652
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non‐invasive quantification of [18F]‐PI‐2620 binding to tau deposits in the brain using an image‐derived input function

Anjan Bhattarai, Emily Nicole Holy, Audrey P. Fan, Guobao Wang et al.
Alzheimer s & Dementia
Medical Imaging Techniques and Applications
article

Non‐invasive quantification of [18F]‐PI‐2620 binding to tau deposits in the brain using an image‐derived input function

Anjan Bhattarai, Emily Nicole Holy, Audrey P. Fan, Guobao Wang, Charles DeCarli, Yiran Wang, Benjamin A. Spencer
article en

Abstract

Abstract Background This study quantified tau binding in the brain with 18 F‐PI2620 PET using a non‐invasive Image‐Derived Input function(IDIF), derived using a new total‐body EXPLORER PET/CT scanner (Spencer et al.,2021). Additionally, we explored how PET scan duration influences the quantification of kinetic parameters across brain regions of interest(ROIs) that are vulnerable in Alzheimer’s Disease. Method The study cohort included 15 individuals (10 cognitively unimpaired, 3 mild cognitive impairment, and 2 AD; ages=68‐92 years; all tau negative) from the UC Davis ADRC. Dynamic total‐body 18 F‐PI‐2620 PET images were acquired over 90 minutes using the uEXPLORER (resolution=2.344 mm isotropic voxels, framing protocol:30×2s,12×10s,7×60s,16×300s). Brain cropped PET images were motion corrected (Jenkinson et al.,2002), and linearly registered to individual T1‐weighted(T1W) MRIs (Jenkinson &amp; Smith, 2001). Grey matter ROIs, including the medial temporal(MT), posterior cingulate(PC), and lateral parietal(LP) cortices, were obtained parcellating T1W images (Desikan et al.,2006). Dynamic time activity curves for each brain ROI were fitted to a reversible two‐tissue compartmental model(2TCM), accounting for delay, using a subject‐specific IDIF(plasma and metabolite‐corrected) derived from the descending aorta of the same images (Figure 1). ROI‐specific micro and macro kinetic parameters were estimated. Logan graphical analysis (Logan,2000) was also used to estimate total distribution volume(V T ). Result 2TCM with IDIF demonstrated high‐quality fits of 18 F‐PI2620 binding across grey matter ROIs (Figure 1). Perfusion (K 1 ) was observed to be reduced in MT compared to PC and LP (Figure 2A). All kinetic parameters remained relatively stable after the 60‐minute scan window across all ROIs. Notably, K 1 showed stability after 30 minutes of scan duration across all ROIs (Figure 2 and 3). A strong correlation was observed between VT estimated using 2TCM and Logan plot analysis, across all ROIs LP(r=1.00, p&lt;0.001), MT(r=0.96, p&lt;0.001), PC(r =1.00, p&lt;0.001). Additionally, significant negative correlation was observed between binding potential and perfusion across all ROIs (r=‐0.40, p=0.007). Conclusion This study highlights the utility of a non‐invasive descending aorta IDIF derived using a total‐body EXPLORER PET/CT scanner to quantify 18 F‐PI‐2620 grey matter kinetics. Preliminary findings suggest that a 60‐minute scan window may be sufficient for reliable quantification of kinetic parameters, while a 30‐minute scan time may suffice for perfusion alone. These findings warrant validation in a cohort involving tau positive individuals.

Alzheimer s & DementiaVol. 20(S2)
University of California, Davis (US)
Openalex Percentile: Top 58%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.