Plasma p‐tau217 outperforms [<sup>18</sup>F]FDG‐PET in identifying biological Alzheimer’s disease in atypical and early‐onset dementia

Abstract Background Biomarkers promise to significantly improve the differential diagnosis of Alzheimer’s disease (AD). Plasma biomarkers, such as phosphorylated tau (p‐tau), have shown potential in diagnosing AD with high accuracy. Unlike the widely‐used [18 F]FDG‐PET diagnostic biomarker in clinical practice, plasma p‐tau is specific to AD and can provide an affordable and scalable diagnostic tool. Method We conducted a retrospective analysis of individuals with atypical dementia, and/or early‐onset dementia cases, who were assessed at a specialized memory clinic. All participants underwent measurements of CSF Aβ42, p‐tau181, and total tau levels, as well as brain [ 18 F]FDG‐PET scans and plasma p‐tau217 measurement. The [ 18 F]FDG‐PET data was visually examined by two nuclear medicine experts to determine whether they were compatible with AD. CSF biomarker results were categorized as either AD biomarker positive or negative. Contingency analysis was performed to assess the relationships between PET scan interpretation and fluid biomarkers (plasma p‐tau217 and CSF p‐tau181 and Aβ42). CSF biomarker and amyloid‐PET were treated as the reference standard. Result 81 subjects with atypical dementia had CSF AD biomarker evaluation, [ 18 F]FDG‐PET rating, and plasma p‐tau217 assessment. Both [ 18 F]FDG‐PET and plasma p‐tau217 had high levels of agreement with reference standard AD biomarkers ([ 18 F]FDG‐PET: 71%; plasma p‐tau217: 81%). Although both biomarkers had similar specificity for AD ([ 18 F]FDG‐PET:70%, plasma p‐tau217:70%), plasma p‐tau217 had higher sensitivity for abnormal AD (97%). Overall accuracy was also higher for plasma p‐tau217 (AUC=84%, 95%CI = 0.75‐ 0.93). The same pattern of results was observed when using amyloid‐PET as the reference standard. Conclusion Our study provides evidence that plasma p‐tau217 has excellent diagnostic performance for AD in individuals with early‐onset or atypical dementia evaluated in specialized settings. Nevertheless, the topographical information from [ 18 F]FDG‐PET may give complementary information.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.093116
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plasma p‐tau217 outperforms [18F]FDG‐PET in identifying biological Alzheimer’s disease in atypical and early‐onset dementia

Serge Gauthier, Tharick Ali Pascoal, Joseph Therriault, Nicholas James Ashton et al.
1 citations
Alzheimer s & Dementia
Medical Imaging Techniques and Applications
0.40
article

Plasma p‐tau217 outperforms [18F]FDG‐PET in identifying biological Alzheimer’s disease in atypical and early‐onset dementia

Serge Gauthier, Tharick Ali Pascoal, Joseph Therriault, Nicholas James Ashton, Jean‐Paul Soucy, Jaime Fernández Arias, Nesrine Rahmouni, Andréa Lessa Benedet, Arthur C. Macedo, Thomas K. Karikari, Cécile Tissot, Henrik Zetterberg, Pedro Rosa‐Neto, Paolo Vitali, Yi‐Ting Wang, Jenna Stevenson, Antonio Aliaga, Kely Monica Quispialaya Socualaya
article en
1 citations

Abstract

Abstract Background Biomarkers promise to significantly improve the differential diagnosis of Alzheimer’s disease (AD). Plasma biomarkers, such as phosphorylated tau (p‐tau), have shown potential in diagnosing AD with high accuracy. Unlike the widely‐used [18 F]FDG‐PET diagnostic biomarker in clinical practice, plasma p‐tau is specific to AD and can provide an affordable and scalable diagnostic tool. Method We conducted a retrospective analysis of individuals with atypical dementia, and/or early‐onset dementia cases, who were assessed at a specialized memory clinic. All participants underwent measurements of CSF Aβ42, p‐tau181, and total tau levels, as well as brain [ 18 F]FDG‐PET scans and plasma p‐tau217 measurement. The [ 18 F]FDG‐PET data was visually examined by two nuclear medicine experts to determine whether they were compatible with AD. CSF biomarker results were categorized as either AD biomarker positive or negative. Contingency analysis was performed to assess the relationships between PET scan interpretation and fluid biomarkers (plasma p‐tau217 and CSF p‐tau181 and Aβ42). CSF biomarker and amyloid‐PET were treated as the reference standard. Result 81 subjects with atypical dementia had CSF AD biomarker evaluation, [ 18 F]FDG‐PET rating, and plasma p‐tau217 assessment. Both [ 18 F]FDG‐PET and plasma p‐tau217 had high levels of agreement with reference standard AD biomarkers ([ 18 F]FDG‐PET: 71%; plasma p‐tau217: 81%). Although both biomarkers had similar specificity for AD ([ 18 F]FDG‐PET:70%, plasma p‐tau217:70%), plasma p‐tau217 had higher sensitivity for abnormal AD (97%). Overall accuracy was also higher for plasma p‐tau217 (AUC=84%, 95%CI = 0.75‐ 0.93). The same pattern of results was observed when using amyloid‐PET as the reference standard. Conclusion Our study provides evidence that plasma p‐tau217 has excellent diagnostic performance for AD in individuals with early‐onset or atypical dementia evaluated in specialized settings. Nevertheless, the topographical information from [ 18 F]FDG‐PET may give complementary information.

Alzheimer s & DementiaVol. 20(S2)
Montreal Neurological Institute and Hospital (CA), Universidade Federal do Rio Grande do Sul (BR), Lawrence Berkeley National Laboratory (US), University of Pittsburgh (US), McGill University (CA), University of Gothenburg (SE)
Openalex Percentile: Top 31%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.