Design and Validation of the ADNI MR Protocol

Abstract Background Phase four of the Alzheimer’s Disease Neuroimaging Initiative (ADNI4) began in 2023. This time‐period corresponded to MRI vendors introducing product sequences with compressed sensing (CS), cross‐vendor adoption of arterial spin‐labelling (ASL) and multi‐band slice excitation, and hardware improvements (head‐coils, increased gradient amplitudes). These advances enabled the acquisition of new imaging measures and reduced scan times. The ADNI4 MRI protocol aims to maintain longitudinal consistency across two decades of data acquisition, while adopting new technologies. Here we describe the design and justification behind the ADNI4 protocol and list the target imaging biomarkers. Methods The ADNI4 MRI protocol includes 9 MRI sequences; i) T1‐weighted (T1w) MP‐RAGE, ii) a compressed sensing T1w MP‐RAGE, iii) 3D T2w FLAIR, iv) structural isotropic 3D T2w v) T2*‐weighted susceptibility imaging vi) multi‐post labelling delay (PLD) 3D ASL, vii) 2D multi‐band‐multiple‐shell diffusion (dMRI), viii) 2D multi‐band EPI BOLD ix) high resolution, limited field of view, imaging centered on the hippocampus. Table 1 gives a detailed summary of the key protocol parameters and lists some of the imaging biomarkers that can be obtained from each series. Results Structural imaging was kept consistent across imaging sites. Variations in vendor specific sequences, software upgrades, and hardware performance capabilities, resulted in variations in advanced imaging strategies. Table 2 highlights the advanced sequences introduced in ADNI4, which will gradually be implemented as the required upgrades and licenses are obtained at each site. The main advanced sequences that are new in ADNI4 from ADNI 3 are i) CS for T1w images, ii) pseudo‐continuous‐ASL (pCASL) being implemented on all 3 vendors (GE, Siemens, Philips), iii) multi‐PLD ASL, which allows for the generation of quantitative maps of cerebral blood‐flow (CBF) and arterial transit times (ATTs), iv) and isotropic 1mm 3 resolution for 3D FLAIR. When ADNI4 began, product sequences that utilized artificial intelligence were not widely available and could not be adequately tested before the rollout of ADNI4. Conclusions The ADNI4 database will continue to help the neuroimaging community, not only extract valuable imaging biomarkers, but provide the data necessary to test the impact of advanced imaging strategies on diagnostic accuracy and disease sensitivity.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.085261
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Validation of the ADNI MR Protocol

Clifford R. Jack, Robert I. Reid, Jeffrey L. Gunter, Randy L. Buckner et al.
Alzheimer s & Dementia
Advanced MRI Techniques and Applications
article

Design and Validation of the ADNI MR Protocol

Clifford R. Jack, Robert I. Reid, Jeffrey L. Gunter, Randy L. Buckner, Bret Borowski, Duygu Tosun, David L. Thomas, Youngkyoo Jung, Arvin Arani, Michael S. W. Weiner, John Felmlee
article en

Abstract

Abstract Background Phase four of the Alzheimer’s Disease Neuroimaging Initiative (ADNI4) began in 2023. This time‐period corresponded to MRI vendors introducing product sequences with compressed sensing (CS), cross‐vendor adoption of arterial spin‐labelling (ASL) and multi‐band slice excitation, and hardware improvements (head‐coils, increased gradient amplitudes). These advances enabled the acquisition of new imaging measures and reduced scan times. The ADNI4 MRI protocol aims to maintain longitudinal consistency across two decades of data acquisition, while adopting new technologies. Here we describe the design and justification behind the ADNI4 protocol and list the target imaging biomarkers. Methods The ADNI4 MRI protocol includes 9 MRI sequences; i) T1‐weighted (T1w) MP‐RAGE, ii) a compressed sensing T1w MP‐RAGE, iii) 3D T2w FLAIR, iv) structural isotropic 3D T2w v) T2*‐weighted susceptibility imaging vi) multi‐post labelling delay (PLD) 3D ASL, vii) 2D multi‐band‐multiple‐shell diffusion (dMRI), viii) 2D multi‐band EPI BOLD ix) high resolution, limited field of view, imaging centered on the hippocampus. Table 1 gives a detailed summary of the key protocol parameters and lists some of the imaging biomarkers that can be obtained from each series. Results Structural imaging was kept consistent across imaging sites. Variations in vendor specific sequences, software upgrades, and hardware performance capabilities, resulted in variations in advanced imaging strategies. Table 2 highlights the advanced sequences introduced in ADNI4, which will gradually be implemented as the required upgrades and licenses are obtained at each site. The main advanced sequences that are new in ADNI4 from ADNI 3 are i) CS for T1w images, ii) pseudo‐continuous‐ASL (pCASL) being implemented on all 3 vendors (GE, Siemens, Philips), iii) multi‐PLD ASL, which allows for the generation of quantitative maps of cerebral blood‐flow (CBF) and arterial transit times (ATTs), iv) and isotropic 1mm 3 resolution for 3D FLAIR. When ADNI4 began, product sequences that utilized artificial intelligence were not widely available and could not be adequately tested before the rollout of ADNI4. Conclusions The ADNI4 database will continue to help the neuroimaging community, not only extract valuable imaging biomarkers, but provide the data necessary to test the impact of advanced imaging strategies on diagnostic accuracy and disease sensitivity.

Alzheimer s & DementiaVol. 20(S2)
University of California, San Francisco (US), Harvard University Press (US), Mayo Clinic in Arizona (US), National Hospital for Neurology and Neurosurgery (GB), Northern California Institute for Research and Education (US), University College London (GB), University of California, Davis (US)
Openalex Percentile: Top 58%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.