Comparative life cycle analysis of Legionella treatment and prevention systems in healthcare buildings DHW facilities

Legionellosis is a disease caused by the Legionella pneumophila bacterium and that has great importance in the different water systems of a hospital's infrastructure. To prevent its appearance and spread, it is necessary for the health system to have preventive maintenance and disinfection equipment. This research evaluated the environmental impact of 5 disinfection systems of the Extremadura Health Service (Spain) broken down into 15 disinfection cases which covered two working scenarios and different types of fuel and chemical consumption. To this end, the different cases underwent a life cycle assessment, and a unique scoring damage category analysis was performed for the midpoint and endpoint stages using the ReCiPe 2016 method, the Ecoinvent 3.10 environmental database, the SimaPro 9.6 LCA software, and the “cradle to grave” perspective. The results show that disinfection using ultraviolet radiation gave the least favourable values in both working scenarios (6.28 pt./m 3 ). In addition, it was determined that the chemical disinfection system through intensive chlorine hyperchlorination is the optimal solution when less than two outbreaks occur each year (1.13 pt./m 3 ). For scenarios with more than two annual outbreaks (unusual situation), the copper‑silver ionization disinfection system is the most sustainable. The knowledge obtained made it possible to add a new dimension to the process of selecting treatment systems against Legionella in hospital water installations, guaranteeing their operability and the health and safety of users. • LCA enables environmental impact assessment of hospital water disinfection systems. • Cradle-to-grave analysis ensures thorough assessment of disinfection sustainability. • UV radiation showed the highest environmental impact in all scenarios. • Chlorine hyperchlorination is optimal for low-outbreak scenarios, minimizing impact. • Copper‑silver ionization is the most sustainable choice in high-outbreak scenarios.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-01-09
DOI
https://doi.org/10.1016/j.jwpe.2025.106946
Citations
1
Primary Topic
Legionella and Acanthamoeba research
Type
article
Field-Weighted Citation Impact
1.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative life cycle analysis of Legionella treatment and prevention systems in healthcare buildings DHW facilities

Francisco J. Rebollo, Manuel Botejara-Antúnez, Justo García‐Sanz‐Calcedo, Jaime González‐Domínguez
1 citations
Journal of Water Process Engineering
Legionella and Acanthamoeba research
1.80
article

Comparative life cycle analysis of Legionella treatment and prevention systems in healthcare buildings DHW facilities

Francisco J. Rebollo, Manuel Botejara-Antúnez, Justo García‐Sanz‐Calcedo, Jaime González‐Domínguez
article en
1 citations

Abstract

Legionellosis is a disease caused by the Legionella pneumophila bacterium and that has great importance in the different water systems of a hospital's infrastructure. To prevent its appearance and spread, it is necessary for the health system to have preventive maintenance and disinfection equipment. This research evaluated the environmental impact of 5 disinfection systems of the Extremadura Health Service (Spain) broken down into 15 disinfection cases which covered two working scenarios and different types of fuel and chemical consumption. To this end, the different cases underwent a life cycle assessment, and a unique scoring damage category analysis was performed for the midpoint and endpoint stages using the ReCiPe 2016 method, the Ecoinvent 3.10 environmental database, the SimaPro 9.6 LCA software, and the “cradle to grave” perspective. The results show that disinfection using ultraviolet radiation gave the least favourable values in both working scenarios (6.28 pt./m 3 ). In addition, it was determined that the chemical disinfection system through intensive chlorine hyperchlorination is the optimal solution when less than two outbreaks occur each year (1.13 pt./m 3 ). For scenarios with more than two annual outbreaks (unusual situation), the copper‑silver ionization disinfection system is the most sustainable. The knowledge obtained made it possible to add a new dimension to the process of selecting treatment systems against Legionella in hospital water installations, guaranteeing their operability and the health and safety of users. • LCA enables environmental impact assessment of hospital water disinfection systems. • Cradle-to-grave analysis ensures thorough assessment of disinfection sustainability. • UV radiation showed the highest environmental impact in all scenarios. • Chlorine hyperchlorination is optimal for low-outbreak scenarios, minimizing impact. • Copper‑silver ionization is the most sustainable choice in high-outbreak scenarios.

Journal of Water Process EngineeringVol. 70
Universidad de Extremadura (ES)
Junta de Extremadura, European Regional Development Fund
Zero hunger
Openalex Percentile: Top 22%
Legionella and Acanthamoeba research
1.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.