Automated stenosis estimation of coronary angiographies using end-to-end learning

The initial evaluation of stenosis during coronary angiography is typically performed by visual assessment. Visual assessment has limited accuracy compared to fractional flow reserve and quantitative coronary angiography, which are more time-consuming and costly. Applying deep learning might yield a faster and more accurate stenosis assessment. We developed a deep learning model to classify cine loops into left or right coronary artery (LCA/RCA) or "other". Data were obtained by manual annotation. Using these classifications, cine loops before revascularization were identified and curated automatically. Separate deep learning models for LCA and RCA were developed to estimate stenosis using these identified cine loops. From a cohort of 19,414 patients and 332,582 cine loops, we identified cine loops for 13,480 patients for model development and 5056 for internal testing. External testing was conducted using automated identified cine loops from 608 patients. For identification of significant stenosis (visual assessment of diameter stenosis > 70%), our model obtained a receiver operator characteristic (ROC) area under the curve (ROC-AUC) of 0.903 (95% CI: 0.900-0.906) on the internal test. The performance was evaluated on the external test set against visual assessment, 3D quantitative coronary angiography, and fractional flow reserve (≤ 0.80), obtaining ROC AUC values of 0.833 (95% CI: 0.814-0.852), 0.798 (95% CI: 0.741-0.842), and 0.780 (95% CI: 0.743-0.817), respectively. The deep-learning-based stenosis estimation models showed promising results for predicting stenosis. Compared to previous work, our approach demonstrates performance increase, includes all 16 segments, does not exclude revascularized patients, is externally tested, and is simpler using fewer steps.

Authors

Institutions

Publication Details

Journal
The International Journal of Cardiovascular Imaging
Published
2025-01-09
DOI
https://doi.org/10.1007/s10554-025-03324-x
Citations
6
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
12.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated stenosis estimation of coronary angiographies using end-to-end learning

Simon Winther, Alex Hørby Christensen, Søren Brunak, Morten Bøttcher et al.
6 citations
The International Journal of Cardiovascular Imaging
Coronary Interventions and Diagnostics
12.04
article

Automated stenosis estimation of coronary angiographies using end-to-end learning

Simon Winther, Alex Hørby Christensen, Søren Brunak, Morten Bøttcher, Peter Bruun‐Rasmussen, Anders Bjorholm Dahl, Lars Køber, Piotr Jaroslaw Chmura, Frants Pedersen, Henning Bundgaard, Thomas Engstrøm, Christian Kim Eschen, Karina Banasik
article en
6 citations

Abstract

The initial evaluation of stenosis during coronary angiography is typically performed by visual assessment. Visual assessment has limited accuracy compared to fractional flow reserve and quantitative coronary angiography, which are more time-consuming and costly. Applying deep learning might yield a faster and more accurate stenosis assessment. We developed a deep learning model to classify cine loops into left or right coronary artery (LCA/RCA) or "other". Data were obtained by manual annotation. Using these classifications, cine loops before revascularization were identified and curated automatically. Separate deep learning models for LCA and RCA were developed to estimate stenosis using these identified cine loops. From a cohort of 19,414 patients and 332,582 cine loops, we identified cine loops for 13,480 patients for model development and 5056 for internal testing. External testing was conducted using automated identified cine loops from 608 patients. For identification of significant stenosis (visual assessment of diameter stenosis > 70%), our model obtained a receiver operator characteristic (ROC) area under the curve (ROC-AUC) of 0.903 (95% CI: 0.900-0.906) on the internal test. The performance was evaluated on the external test set against visual assessment, 3D quantitative coronary angiography, and fractional flow reserve (≤ 0.80), obtaining ROC AUC values of 0.833 (95% CI: 0.814-0.852), 0.798 (95% CI: 0.741-0.842), and 0.780 (95% CI: 0.743-0.817), respectively. The deep-learning-based stenosis estimation models showed promising results for predicting stenosis. Compared to previous work, our approach demonstrates performance increase, includes all 16 segments, does not exclude revascularized patients, is externally tested, and is simpler using fewer steps.

The International Journal of Cardiovascular ImagingVol. 41(3)
University of Copenhagen (DK), Aarhus University (DK), Novo Nordisk Foundation (DK), Gentofte Hospital (DK), Rigshospitalet (DK), Technical University of Denmark (DK)
Innovationsfonden, Københavns Universitet, Novo Nordisk, Novo Nordisk Fonden
Openalex Percentile: Top 2%
Coronary Interventions and Diagnostics
12.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.