Point-of-care testing of methotrexate using a controlled release sensor based on a personal glucose meter

Methotrexate (MTX), a widely administered medication for treating an array of tumors and autoimmune disorders, necessitates stringent monitoring due to the potential for severe adverse effects associated with its high dosage. Nevertheless, the existing methods for monitoring MTX are often intricate, time-consuming and incur significant costs. In this work, we constructed a controlled release sensor, harnessing the versatility of a personal glucose meter (PGM), which had been devised for the swift detection of MTX. This innovative approach employed HP-UiO-66-NH<sub>2</sub> as a nanoscale reservoir for glucose encapsulation, with aptamer-conjugated gold nanoparticles (AuNPs@Apt) serving as molecular gates, sealing the pores of the nano-container. Upon the introduction of MTX into the solution, a specific recognition event occurred between the aptamer and MTX, leading to the formation of a stable AuNPs@Apt-MTX complex. This interaction triggered the release of AuNPs@Apt from the surface of HP-UiO-66-NH<sub>2</sub>, allowing glucose to escape, which was then detected by the PGM. This method demonstrated a robust linear response to MTX concentrations spanning from 0.1 μM to 20 μM, with a remarkable detection limit of 0.1 μM. Extensive experiments underscored the platform's exceptional selectivity for MTX detection, coupled with excellent reproducibility and stability, with a detection time of only 30 minutes. Importantly, it had been successfully applied to the analysis of MTX in diluted human serum with satisfactory recoveries. Given its portability and cost-effectiveness, this platform paved a novel avenue for monitoring MTX blood drug levels, offering significant potential for clinical applications and drug monitoring strategies.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d4ay02038c
Citations
2
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Point-of-care testing of methotrexate using a controlled release sensor based on a personal glucose meter

Danqun Huo, Huanbao Fa, Yongzhong Wang, Changjun Hou et al.
2 citations
Analytical Methods
Wireless Body Area Networks
1.35
article

Point-of-care testing of methotrexate using a controlled release sensor based on a personal glucose meter

Danqun Huo, Huanbao Fa, Yongzhong Wang, Changjun Hou, Lauren M. Zhao, Mei Yang, Ting Zhang, Liyu Yang, Siyi Yang
article en
2 citations

Abstract

Methotrexate (MTX), a widely administered medication for treating an array of tumors and autoimmune disorders, necessitates stringent monitoring due to the potential for severe adverse effects associated with its high dosage. Nevertheless, the existing methods for monitoring MTX are often intricate, time-consuming and incur significant costs. In this work, we constructed a controlled release sensor, harnessing the versatility of a personal glucose meter (PGM), which had been devised for the swift detection of MTX. This innovative approach employed HP-UiO-66-NH<sub>2</sub> as a nanoscale reservoir for glucose encapsulation, with aptamer-conjugated gold nanoparticles (AuNPs@Apt) serving as molecular gates, sealing the pores of the nano-container. Upon the introduction of MTX into the solution, a specific recognition event occurred between the aptamer and MTX, leading to the formation of a stable AuNPs@Apt-MTX complex. This interaction triggered the release of AuNPs@Apt from the surface of HP-UiO-66-NH<sub>2</sub>, allowing glucose to escape, which was then detected by the PGM. This method demonstrated a robust linear response to MTX concentrations spanning from 0.1 μM to 20 μM, with a remarkable detection limit of 0.1 μM. Extensive experiments underscored the platform's exceptional selectivity for MTX detection, coupled with excellent reproducibility and stability, with a detection time of only 30 minutes. Importantly, it had been successfully applied to the analysis of MTX in diluted human serum with satisfactory recoveries. Given its portability and cost-effectiveness, this platform paved a novel avenue for monitoring MTX blood drug levels, offering significant potential for clinical applications and drug monitoring strategies.

Analytical MethodsVol. 17(6)
Chongqing University (CN)
National Natural Science Foundation of China, Chongqing Science and Technology Commission, National Key Research and Development Program of China, Major Science and Technology Projects in Yunnan Province
Good health and well-being
Openalex Percentile: Top 23%
Wireless Body Area Networks
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.