CH<sub>4</sub>/C<sub>2</sub>H<sub>6</sub> Dual Gas Detection System for Urban Natural Gas Inspection Based on Off‐Axis Integrated Cavity Output Spectroscopy

ABSTRACT A near‐infrared off‐axis integrated cavity output spectroscopic (OA‐ICOS) dual‐gas sensor for methane (CH 4 ) and ethane (C 2 H 6 ) measurement was developed. Utilizing time‐division multiplexing (WDM) technology, dual‐gas detection was realized via the sensor system. The power distribution circuit was improved to make power distribution more reasonable and ripple smaller. The limit of detection (LoD) of C 2 H 6 was effectively reduced by a new calibration method. With an averaging time of 1 s, the LoD is 1.2 parts‐per‐billion (ppb) for CH 4 and 12.1 ppb for C 2 H 6 . Extensive urban measurement unveiled three CH 4 anomalies, while the measured C 2 H 6 levels demonstrated good capability of the sensor system for dual‐gas measurement.

Authors

Institutions

Publication Details

Journal
Microwave and Optical Technology Letters
Published
2025-01-01
DOI
https://doi.org/10.1002/mop.70083
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CH4/C2H6 Dual Gas Detection System for Urban Natural Gas Inspection Based on Off‐Axis Integrated Cavity Output Spectroscopy

Zixun Geng, Zhening Zhang, Zhao Hui Huang, Chuantao Zheng et al.
Microwave and Optical Technology Letters
Spectroscopy and Laser Applications
article

CH4/C2H6 Dual Gas Detection System for Urban Natural Gas Inspection Based on Off‐Axis Integrated Cavity Output Spectroscopy

Zixun Geng, Zhening Zhang, Zhao Hui Huang, Chuantao Zheng, Yiding Wang, Lei Zhang, Yishen Zhou
article en

Abstract

ABSTRACT A near‐infrared off‐axis integrated cavity output spectroscopic (OA‐ICOS) dual‐gas sensor for methane (CH 4 ) and ethane (C 2 H 6 ) measurement was developed. Utilizing time‐division multiplexing (WDM) technology, dual‐gas detection was realized via the sensor system. The power distribution circuit was improved to make power distribution more reasonable and ripple smaller. The limit of detection (LoD) of C 2 H 6 was effectively reduced by a new calibration method. With an averaging time of 1 s, the LoD is 1.2 parts‐per‐billion (ppb) for CH 4 and 12.1 ppb for C 2 H 6 . Extensive urban measurement unveiled three CH 4 anomalies, while the measured C 2 H 6 levels demonstrated good capability of the sensor system for dual‐gas measurement.

Microwave and Optical Technology LettersVol. 67(1)
Jilin University (CN), State Key Laboratory on Integrated Optoelectronics (CN)
Sustainable cities and communities
Openalex Percentile: Top 100%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CH<sub>4</sub>/C<sub>2</sub>H<sub>6</sub> Dual Gas Detection System for Urban Natural Gas Inspection Based on Off‐Axis Integrated Cavity Output Spectroscopy — Zixun Geng, Zhening Zhang, et al. · Microwave and Optical Technology Letters (2025) | TGRS Research Map | TGRS