An investigation on the uncertainty of fill factor

This study focuses on the fill factor ( FF ) measurement uncertainty contributing to the uncertainty in the labeling of the nominal maximum power ( P max ) of photovoltaic modules, which is determined under Standard Test Conditions (STC). Given that the price of these modules is tied to their P max , accurately quantifying the uncertainty of this measurement is crucial for ISO/IEC 17025 accredited laboratories. Adhering to the “Guide to the expression of uncertainty in measurement”, this work evaluates the uncertainty contribution of the Fill Factor ( FF ), a key parameter linking P max , the open-circuit voltage ( V oc ), and the short-circuit current ( I sc ). The analysis is based on data from three reference modules measured at the European Solar Test Installation (ESTI), part of the Joint Research Centre of the European Commission, since 1996. This data shows a reduction in FF uncertainty from approximately 0.6% to 0.3%, attributed to advancements in measurement technologies and techniques. Considering the goal of top calibration laboratories to measure P max with the lowest possible uncertainty, the improvement in FF uncertainty measurement is significant, ensuring more accurate labeling of photovoltaic modules.

Authors

Institutions

Publication Details

Journal
EPJ Photovoltaics
Published
2025-01-01
DOI
https://doi.org/10.1051/epjpv/2024042
Primary Topic
Electronic Packaging and Soldering Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An investigation on the uncertainty of fill factor

Tony Sample, Diego Pavanello, Harald Müllejans
EPJ Photovoltaics
Electronic Packaging and Soldering Technologies
article

An investigation on the uncertainty of fill factor

Tony Sample, Diego Pavanello, Harald Müllejans
article en

Abstract

This study focuses on the fill factor ( FF ) measurement uncertainty contributing to the uncertainty in the labeling of the nominal maximum power ( P max ) of photovoltaic modules, which is determined under Standard Test Conditions (STC). Given that the price of these modules is tied to their P max , accurately quantifying the uncertainty of this measurement is crucial for ISO/IEC 17025 accredited laboratories. Adhering to the “Guide to the expression of uncertainty in measurement”, this work evaluates the uncertainty contribution of the Fill Factor ( FF ), a key parameter linking P max , the open-circuit voltage ( V oc ), and the short-circuit current ( I sc ). The analysis is based on data from three reference modules measured at the European Solar Test Installation (ESTI), part of the Joint Research Centre of the European Commission, since 1996. This data shows a reduction in FF uncertainty from approximately 0.6% to 0.3%, attributed to advancements in measurement technologies and techniques. Considering the goal of top calibration laboratories to measure P max with the lowest possible uncertainty, the improvement in FF uncertainty measurement is significant, ensuring more accurate labeling of photovoltaic modules.

EPJ PhotovoltaicsVol. 16
Joint Research Centre (IT)
European Commission, Joint Research Centre
Openalex Percentile: Top 100%
Electronic Packaging and Soldering Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.