Reversing LeTID in PV power plants: a feasibility study

Light and elevated Temperature Induced Degradation (LeTID) is likely causing strong yield losses in a significant number of photovoltaic (PV) power plants which were commissioned in the late 2010s. In this work, a procedure for an in-field recovery using overnight current injection to trigger temporary recovery of LeTID is presented. The general feasibility of such a procedure is first demonstrated by climatic chamber experiments on strongly degraded mc-Si PERC PV modules. Within the screened test conditions, a temporary recovery procedure with high currents and low module temperatures is most promising for an economic application in PV power plants. An outdoor experiment with current injection during nights and MPP tracking during days confirmed the possibility to recover LeTID in PV power plants. By injecting a pulsed current, the heating of the modules caused by the current injection was strongly reduced compared to the heating at constant current injection. Recommendations for the application of a procedure in PV power plants are given based on the required energy expenditure and cost.

Authors

Institutions

Publication Details

Journal
EPJ Photovoltaics
Published
2025-01-01
DOI
https://doi.org/10.1051/epjpv/2024044
Citations
1
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reversing LeTID in PV power plants: a feasibility study

Thomas Mikolajick, Daniel Philipp, Cornelius Armbruster, Erdmut Schnabel et al.
1 citations
EPJ Photovoltaics
Photovoltaic System Optimization Techniques
0.36
article

Reversing LeTID in PV power plants: a feasibility study

Thomas Mikolajick, Daniel Philipp, Cornelius Armbruster, Erdmut Schnabel, Viktor Wesselak, Paul Gebhardt, Esther Fokuhl, Alexander Kleinhans
article en
1 citations

Abstract

Light and elevated Temperature Induced Degradation (LeTID) is likely causing strong yield losses in a significant number of photovoltaic (PV) power plants which were commissioned in the late 2010s. In this work, a procedure for an in-field recovery using overnight current injection to trigger temporary recovery of LeTID is presented. The general feasibility of such a procedure is first demonstrated by climatic chamber experiments on strongly degraded mc-Si PERC PV modules. Within the screened test conditions, a temporary recovery procedure with high currents and low module temperatures is most promising for an economic application in PV power plants. An outdoor experiment with current injection during nights and MPP tracking during days confirmed the possibility to recover LeTID in PV power plants. By injecting a pulsed current, the heating of the modules caused by the current injection was strongly reduced compared to the heating at constant current injection. Recommendations for the application of a procedure in PV power plants are given based on the required energy expenditure and cost.

EPJ PhotovoltaicsVol. 16
Nordhausen University of Applied Sciences (DE), Fraunhofer Institute for Solar Energy Systems (DE), Technische Universität Dresden (DE)
Affordable and clean energy
Openalex Percentile: Top 47%
Photovoltaic System Optimization Techniques
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reversing LeTID in PV power plants: a feasibility study — Thomas Mikolajick, Daniel Philipp, et al. · EPJ Photovoltaics (2025) | TGRS Research Map | TGRS