Membrane-based fibre Fabry-Perot cavity hydrophone with high sensitivity

In this paper, a high-sensitivity fibre Fabry Perot (FP) cavity hydrophone is investigated, which uses a metal film as the sensitive acoustic wave element. The end face of the optical fibre is coated with a high refractive index dielectric film to form an interference structure of the FP cavity. And water is used to fill the FP cavity to balance the pressure difference between the inside and outside of the cavity. The sensitivity, frequency response, and hydrostatic pressure resistance of fibre FP cavity hydrophones are characterized with self-built setup. The membrane-based fibre FP cavity hydrophone showed a high sensitivity of -137 dB re 1V/μPa@100 Hz, and can withstand hydrostatic pressure up to 120 Mpa, which is a depth of 12000 m water.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.2812
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Membrane-based fibre Fabry-Perot cavity hydrophone with high sensitivity

Mingkai Gu, Yue Liu, Hao Li, Junming Li et al.
IET conference proceedings.
Advanced Fiber Optic Sensors
article

Membrane-based fibre Fabry-Perot cavity hydrophone with high sensitivity

Mingkai Gu, Yue Liu, Hao Li, Junming Li, Jin Cheng
article en

Abstract

In this paper, a high-sensitivity fibre Fabry Perot (FP) cavity hydrophone is investigated, which uses a metal film as the sensitive acoustic wave element. The end face of the optical fibre is coated with a high refractive index dielectric film to form an interference structure of the FP cavity. And water is used to fill the FP cavity to balance the pressure difference between the inside and outside of the cavity. The sensitivity, frequency response, and hydrostatic pressure resistance of fibre FP cavity hydrophones are characterized with self-built setup. The membrane-based fibre FP cavity hydrophone showed a high sensitivity of -137 dB re 1V/μPa@100 Hz, and can withstand hydrostatic pressure up to 120 Mpa, which is a depth of 12000 m water.

IET conference proceedings.Vol. 2024(9)
Beijing Information Science & Technology University (CN)
Openalex Percentile: Top 100%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Membrane-based fibre Fabry-Perot cavity hydrophone with high sensitivity — Mingkai Gu, Yue Liu, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS