A study of ionisation chamber energy response measurements based on monoenergetic X-ray

Ionisation chambers, as an important tool for radiation measurements, are particularly critical in terms of their energy response characteristics, while monoenergetic X-ray have the advantages of continuous and adjustable energy, large injections and good stability compared to conventional radioactive sources. In this study, a high-pressure gas ionisation chamber is measured and its energy response is calculated using a monoenergetic X-ray device, and the data are plotted and compared with those from Monte Carlo simulations to validate the feasibility of the measurement study using a monoenergetic X-ray device. The study proposes to calibrate the energy response of the ionisation chamber by counting with a standard high-purity germanium detector and using the ratio of its omnipotent peak detection efficiency as the true value. The conclusions show that the experimental and simulated curves follow the same trend, with an overall increase with increasing energy, especially in the medium energy region (15 keV-25 keV) where the trends of the normalised energy response curves are roughly in agreement, demonstrating the feasibility of using a monoenergetic X-ray device to measure the energy response of ionisation chambers.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.2767
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A study of ionisation chamber energy response measurements based on monoenergetic X-ray

Zhongtao Wang, Zhiwei Li, Zhen Wang, Siming Guo
IET conference proceedings.
Radiation Detection and Scintillator Technologies
article

A study of ionisation chamber energy response measurements based on monoenergetic X-ray

Zhongtao Wang, Zhiwei Li, Zhen Wang, Siming Guo
article en

Abstract

Ionisation chambers, as an important tool for radiation measurements, are particularly critical in terms of their energy response characteristics, while monoenergetic X-ray have the advantages of continuous and adjustable energy, large injections and good stability compared to conventional radioactive sources. In this study, a high-pressure gas ionisation chamber is measured and its energy response is calculated using a monoenergetic X-ray device, and the data are plotted and compared with those from Monte Carlo simulations to validate the feasibility of the measurement study using a monoenergetic X-ray device. The study proposes to calibrate the energy response of the ionisation chamber by counting with a standard high-purity germanium detector and using the ratio of its omnipotent peak detection efficiency as the true value. The conclusions show that the experimental and simulated curves follow the same trend, with an overall increase with increasing energy, especially in the medium energy region (15 keV-25 keV) where the trends of the normalised energy response curves are roughly in agreement, demonstrating the feasibility of using a monoenergetic X-ray device to measure the energy response of ionisation chambers.

IET conference proceedings.Vol. 2024(9)
Chengdu University of Technology (CN), National Institute of Metrology (CN)
Affordable and clean energy
Openalex Percentile: Top 99%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.