Design of high uniformity magnetic field coils for magnetoencephalography measurement

The uniformity of the central region within a magnetic shielding room (MSR) is a critical factor affecting the accuracy of magnetoencephalography (MEG) measurement. High uniformity coil design is a key technology for obtaining the required magnetic field environment. This paper introduces a design method of the high uniformity planar coil based on bat algorithm (BA), which significantly enhances the uniformity of the target region. Based on the target field method, a dual-plane coil generating uniform magnetic fields in the x, y, and z directions was designed. Each directional coil consists of a primary coil and a secondary coil. The Bat Optimization Algorithm was used to optimize the distances from the primary and secondary coils to the center point. Finally, the coil structure was simulated and analyzed using electromagnetic simulation software. The results demonstrate a substantial improvement in uniformity by 38% and 40% in the Bx (By) and Bz directions, respectively, compared to coils designed using traditional TFMs. Therefore, the coil system designed using this method can provide a better zero magnetic field environment for the signal acquisition of magnetoencephalography (MEG).

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.2766
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of high uniformity magnetic field coils for magnetoencephalography measurement

Pengfei Song, Xikai Liu, Wen Tong, Yimin Chen et al.
IET conference proceedings.
Atomic and Subatomic Physics Research
article

Design of high uniformity magnetic field coils for magnetoencephalography measurement

Pengfei Song, Xikai Liu, Wen Tong, Yimin Chen, Liming Wang, Liu Zhang, Ya Deng
article en

Abstract

The uniformity of the central region within a magnetic shielding room (MSR) is a critical factor affecting the accuracy of magnetoencephalography (MEG) measurement. High uniformity coil design is a key technology for obtaining the required magnetic field environment. This paper introduces a design method of the high uniformity planar coil based on bat algorithm (BA), which significantly enhances the uniformity of the target region. Based on the target field method, a dual-plane coil generating uniform magnetic fields in the x, y, and z directions was designed. Each directional coil consists of a primary coil and a secondary coil. The Bat Optimization Algorithm was used to optimize the distances from the primary and secondary coils to the center point. Finally, the coil structure was simulated and analyzed using electromagnetic simulation software. The results demonstrate a substantial improvement in uniformity by 38% and 40% in the Bx (By) and Bz directions, respectively, compared to coils designed using traditional TFMs. Therefore, the coil system designed using this method can provide a better zero magnetic field environment for the signal acquisition of magnetoencephalography (MEG).

IET conference proceedings.Vol. 2024(9)
Ningbo University of Technology (CN), Beihang University (CN)
Openalex Percentile: Top 99%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of high uniformity magnetic field coils for magnetoencephalography measurement — Pengfei Song, Xikai Liu, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS