Lightweight semi-open magnetic shielding room based on finite element method

Lightweight magnetic shielding room (MSR) requires less material, is lighter, more mobile and more cost effective. It will provide a viable solution for portable mobile biomagnetic measurement equipments. In this paper, a semi-open lightweight MSR is proposed based on the finite element method. It uses 30% less permalloy compared to conventional magnetic shielding chambers. We analysed the internal residual magnetism distribution of MSRs under different hole distribution methods through finite element simulation, through which we optimized the structure of MSRs and machined and designed the semi-open MSR. The design has a shielding factor of 26 at 0.1 Hz magnetic field, which is close to the shielding factor of a conventional closed MSR, and provides better ventilation and lighting performance.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.2718
Primary Topic
Inertial Sensor and Navigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightweight semi-open magnetic shielding room based on finite element method

Hongwei Ma, Bing Han, Pengfei Song, Xikai Liu et al.
2 links
IET conference proceedings.
Inertial Sensor and Navigation
article

Lightweight semi-open magnetic shielding room based on finite element method

Hongwei Ma, Bing Han, Pengfei Song, Xikai Liu, Shengyi Shangguan, Shuai Dou, Shengjie Qiu
article en

Abstract

Lightweight magnetic shielding room (MSR) requires less material, is lighter, more mobile and more cost effective. It will provide a viable solution for portable mobile biomagnetic measurement equipments. In this paper, a semi-open lightweight MSR is proposed based on the finite element method. It uses 30% less permalloy compared to conventional magnetic shielding chambers. We analysed the internal residual magnetism distribution of MSRs under different hole distribution methods through finite element simulation, through which we optimized the structure of MSRs and machined and designed the semi-open MSR. The design has a shielding factor of 26 at 0.1 Hz magnetic field, which is close to the shielding factor of a conventional closed MSR, and provides better ventilation and lighting performance.

IET conference proceedings.Vol. 2024(9)
Ningbo University of Technology (CN), Beihang University (CN)
Openalex Percentile: Top 100%
Inertial Sensor and Navigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lightweight semi-open magnetic shielding room based on finite element method — Hongwei Ma, Bing Han, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS