Evaluation of Radiation Safety for Hospital Staff Using Dosimetric Data

Hospitals utilize various manmade radiation sources for therapeutic and sterilization purposes. However, improper monitoring of these sources can lead to radiation leakage, posing potential health risks. At Bir Hospital, data from dosimeters were analysed using appropriate statistical methods. The analysis revealed that the overall absorbed dose is 0.078 mSv per year, well below the 20 mSv annual dose limit recommended by the International Commission on Radiological Protection (ICRP). This indicates that the staff at Bir Hospital are working under safe radiation exposure levels. A Chi-square test further confirmed that there is no significant gender-based variation in radiation dose absorption among the staff. These findings demonstrate that the hospital’s radiation safety measures are effective, ensuring the safety of its employees. This data underscores the importance of maintaining and monitoring radiation safety. To enhance safety standards, it is recommended that all hospitals require medical staff to use dosimeters and provide access to dosimeter data for research and analysis.

Authors

Institutions

Publication Details

Journal
Amrit Research Journal
Published
2024-12-31
DOI
https://doi.org/10.3126/arj.v5i1.73565
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Radiation Safety for Hospital Staff Using Dosimetric Data

Narendra Khadka, Maha Prasad Koirala, Bijaya Neupane, Hom Bahadur Baniya et al.
Amrit Research Journal
Radiation Dose and Imaging
article

Evaluation of Radiation Safety for Hospital Staff Using Dosimetric Data

Narendra Khadka, Maha Prasad Koirala, Bijaya Neupane, Hom Bahadur Baniya, Suman Amgain, Smriti Baniya
article en

Abstract

Hospitals utilize various manmade radiation sources for therapeutic and sterilization purposes. However, improper monitoring of these sources can lead to radiation leakage, posing potential health risks. At Bir Hospital, data from dosimeters were analysed using appropriate statistical methods. The analysis revealed that the overall absorbed dose is 0.078 mSv per year, well below the 20 mSv annual dose limit recommended by the International Commission on Radiological Protection (ICRP). This indicates that the staff at Bir Hospital are working under safe radiation exposure levels. A Chi-square test further confirmed that there is no significant gender-based variation in radiation dose absorption among the staff. These findings demonstrate that the hospital’s radiation safety measures are effective, ensuring the safety of its employees. This data underscores the importance of maintaining and monitoring radiation safety. To enhance safety standards, it is recommended that all hospitals require medical staff to use dosimeters and provide access to dosimeter data for research and analysis.

Amrit Research JournalVol. 5(1)
Tribhuvan University (NP)
Good health and well-being
Openalex Percentile: Top 58%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.