Sensitivity analysis for optimizing magnetic bead recoveries in a flow-through fluorescence immunoassay analyser

The recovery rate of magnetic beads is a crucial factor in evaluating the performance of a flow fluorescence immunoassay analyzer. This paper proposes an optimal design method for an immunoassay analyzer using orthogonal testing and comprehensive sensitivity analysis. The orthogonal experimental design was employed to reduce the number of sensitivity analysis tests required for key design parameters of the flow fluorescence immunoassay analyzer. Through rigorous sensitivity analysis and comprehensive evaluation, the optimal combination of adsorption height, liquid volume, and adsorption time was determined. The experimental results demonstrate that this optimal combination design can significantly improve the recovery rate of magnetic beads. This method provides a novel approach to optimizing the performance of immunoassay analyzers.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.3558
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity analysis for optimizing magnetic bead recoveries in a flow-through fluorescence immunoassay analyser

Le Chang, Rongxue Wei, Zhonglai Wang, Ziyi Zhao
IET conference proceedings.
Non-Destructive Testing Techniques
article

Sensitivity analysis for optimizing magnetic bead recoveries in a flow-through fluorescence immunoassay analyser

Le Chang, Rongxue Wei, Zhonglai Wang, Ziyi Zhao
article en

Abstract

The recovery rate of magnetic beads is a crucial factor in evaluating the performance of a flow fluorescence immunoassay analyzer. This paper proposes an optimal design method for an immunoassay analyzer using orthogonal testing and comprehensive sensitivity analysis. The orthogonal experimental design was employed to reduce the number of sensitivity analysis tests required for key design parameters of the flow fluorescence immunoassay analyzer. Through rigorous sensitivity analysis and comprehensive evaluation, the optimal combination of adsorption height, liquid volume, and adsorption time was determined. The experimental results demonstrate that this optimal combination design can significantly improve the recovery rate of magnetic beads. This method provides a novel approach to optimizing the performance of immunoassay analyzers.

IET conference proceedings.Vol. 2024(12)
University of Electronic Science and Technology of China (CN)
Openalex Percentile: Top 100%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.