Sex-related differences in motor unit firing rate and pennation angle

Motor unit firing rate (MUFR) and pennation angle were measured concurrently in males and females from submaximal to maximal intensities. Thirty participants, (16 female, 14 male) performed isometric dorsiflexion contractions at 20%, 40%, 60%, 80%, and 100% of maximal voluntary contraction (MVC). During each contraction, measures of MUFR were obtained via surface electromyography decomposition, and muscle fiber pennation angle and fascicle length were obtained via ultrasound. There was no significant interaction effect of sex and contraction intensity present for mean MUFR (<i>p</i> = 0.24), pennation angle (<i>p</i> = 0.98), or fascicle length (<i>p</i> = 0.81). Males had greater mean MUFR (<i>p</i> < 0.001), pennation angle (<i>p</i> = 0.02), and fascicle length (<i>p</i> = 0.03) compared to females. In general, mean MUFR (<i>p</i> < 0.001) and pennation angle (<i>p</i> < 0.02) increased with increasing contraction intensity; however, fascicle length (<i>p</i> = 0.30) was similar across contraction intensities. There were no significant relationships between mean MUFR and pennation angle for males (<i>r</i> = 0.18, <i>p</i> = 0.13) or females (<i>r</i> = 0.20, <i>p</i> = 0.09), nor between mean MUFR and fascicle length for males (<i>r</i> = 0.20, <i>p</i> = 0.10) or females (<i>r</i> = 0.21, <i>p</i> = 0.07). Although sex-related differences in MUFR, pennation angle, and fascicle length were present, there were no relationships between MUFR and the muscle properties. These results suggest that sex-related differences in mean MUFR may not be associated with the sex-related differences in the muscle architectural properties currently investigated.

Authors

Institutions

Publication Details

Journal
Applied Physiology Nutrition and Metabolism
Published
2025-01-01
DOI
https://doi.org/10.1139/apnm-2024-0202
Citations
4
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
2.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sex-related differences in motor unit firing rate and pennation angle

Michael J. Marsala, Anita Christie, Alicia M. Kells
4 citations
Applied Physiology Nutrition and Metabolism
Muscle activation and electromyography studies
2.70
article

Sex-related differences in motor unit firing rate and pennation angle

Michael J. Marsala, Anita Christie, Alicia M. Kells
article en
4 citations

Abstract

Motor unit firing rate (MUFR) and pennation angle were measured concurrently in males and females from submaximal to maximal intensities. Thirty participants, (16 female, 14 male) performed isometric dorsiflexion contractions at 20%, 40%, 60%, 80%, and 100% of maximal voluntary contraction (MVC). During each contraction, measures of MUFR were obtained via surface electromyography decomposition, and muscle fiber pennation angle and fascicle length were obtained via ultrasound. There was no significant interaction effect of sex and contraction intensity present for mean MUFR (<i>p</i> = 0.24), pennation angle (<i>p</i> = 0.98), or fascicle length (<i>p</i> = 0.81). Males had greater mean MUFR (<i>p</i> < 0.001), pennation angle (<i>p</i> = 0.02), and fascicle length (<i>p</i> = 0.03) compared to females. In general, mean MUFR (<i>p</i> < 0.001) and pennation angle (<i>p</i> < 0.02) increased with increasing contraction intensity; however, fascicle length (<i>p</i> = 0.30) was similar across contraction intensities. There were no significant relationships between mean MUFR and pennation angle for males (<i>r</i> = 0.18, <i>p</i> = 0.13) or females (<i>r</i> = 0.20, <i>p</i> = 0.09), nor between mean MUFR and fascicle length for males (<i>r</i> = 0.20, <i>p</i> = 0.10) or females (<i>r</i> = 0.21, <i>p</i> = 0.07). Although sex-related differences in MUFR, pennation angle, and fascicle length were present, there were no relationships between MUFR and the muscle properties. These results suggest that sex-related differences in mean MUFR may not be associated with the sex-related differences in the muscle architectural properties currently investigated.

Applied Physiology Nutrition and MetabolismVol. 50
Western University (CA)
Openalex Percentile: Top 12%
Muscle activation and electromyography studies
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sex-related differences in motor unit firing rate and pennation angle — Michael J. Marsala, Anita Christie, et al. · Applied Physiology Nutrition and Metabolism (2025) | TGRS Research Map | TGRS