Energy efficiency and air distribution characteristics of jet ventilation in crossflow for long-narrow mining working faces

Long-term exposure to extreme heat in mines jeopardizes worker health and reduces productivity. This study introduces and evaluates the air distribution of jet ventilation in crossflow (JVIC) mode for localized mine cooling. Experimental and numerical simulations reveal two distinct wake structures: single wakes for wall-attached and impinging jets, and double wakes for deflected jets, influenced by counter-rotating vortex pair (CVP) structures, which accelerate cooling loss. Key parameters—jet-to-crossflow velocity ratio (R), vent equivalent diameter-to-roadway height ratio (C), and jet-to-crossflow Reynolds number ratio—govern flow modes and CVP dynamics, while jet-to-crossflow temperature ratio (T) primarily affects cooling distribution within the jet, confirming a velocity-dominated flow field. A quantitative model was developed to characterize JVIC air distribution, detailing boundaries, diffusion widths, and velocity and temperature trajectories. The model demonstrates that wall-attached and highly deflected jets enable more stable cooling with slower diffusion and reduced energy loss. Under conditions of R = 1 and C = 3, the jet achieves the highest local cooling effectiveness (εt), maintaining a cooling efficiency of 29.9% at x/dm = 3, demonstrating JVIC's ability to maintain effective cooling over extended distances. A practical evaluation shows that the novel JVIC mode achieves a cooling load of 184.9 kW, reducing energy consumption by 86.7% compared to traditional full-air cooling (1387 kW). These findings highlight JVIC's potential for efficient, targeted mine ventilation, advancing cooling efficiency and energy conservation.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-01-01
DOI
https://doi.org/10.1063/5.0246257
Citations
2
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
2.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy efficiency and air distribution characteristics of jet ventilation in crossflow for long-narrow mining working faces

Gang Bai, Fankang Meng, Jue Wang, Jiang Cheng et al.
2 citations
Physics of Fluids
Fire dynamics and safety research
2.61
article

Energy efficiency and air distribution characteristics of jet ventilation in crossflow for long-narrow mining working faces

Gang Bai, Fankang Meng, Jue Wang, Jiang Cheng, Guang Yang, Shixuan Yu, Jiayu Kang
article en
2 citations

Abstract

Long-term exposure to extreme heat in mines jeopardizes worker health and reduces productivity. This study introduces and evaluates the air distribution of jet ventilation in crossflow (JVIC) mode for localized mine cooling. Experimental and numerical simulations reveal two distinct wake structures: single wakes for wall-attached and impinging jets, and double wakes for deflected jets, influenced by counter-rotating vortex pair (CVP) structures, which accelerate cooling loss. Key parameters—jet-to-crossflow velocity ratio (R), vent equivalent diameter-to-roadway height ratio (C), and jet-to-crossflow Reynolds number ratio—govern flow modes and CVP dynamics, while jet-to-crossflow temperature ratio (T) primarily affects cooling distribution within the jet, confirming a velocity-dominated flow field. A quantitative model was developed to characterize JVIC air distribution, detailing boundaries, diffusion widths, and velocity and temperature trajectories. The model demonstrates that wall-attached and highly deflected jets enable more stable cooling with slower diffusion and reduced energy loss. Under conditions of R = 1 and C = 3, the jet achieves the highest local cooling effectiveness (εt), maintaining a cooling efficiency of 29.9% at x/dm = 3, demonstrating JVIC's ability to maintain effective cooling over extended distances. A practical evaluation shows that the novel JVIC mode achieves a cooling load of 184.9 kW, reducing energy consumption by 86.7% compared to traditional full-air cooling (1387 kW). These findings highlight JVIC's potential for efficient, targeted mine ventilation, advancing cooling efficiency and energy conservation.

Physics of FluidsVol. 37(1)
Liaoning Technical University (CN)
Scientific Research Fund of Liaoning Provincial Education Department, National Outstanding Youth Science Fund Project of National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 14%
Fire dynamics and safety research
2.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.