Research on Algorithms for Calibration of Laser Scanning Projection System

The calibration process of laser scanning projection system requires accurate positioning of cooperative targets and precise calculation of coordinate transformation equations. Therefore, this study analyzed the main causes of projection distortion in laser scanning projectors based on a dual-axis galvanometer, established a corresponding mathematical model, optimized the coordinate transformation equation used for calibration, and studied the use of an adaptive weight particle swarm optimization algorithm for its calculation. Meanwhile, the study also explored the Otsu-optimized Canny operator and combined it with the Delaunay triangulation algorithm to process the scanning detection data of cooperative targets and quickly extract their center coordinates. The comprehensive application of these algorithms was experimentally validated using actual measurement data, and the results indicated that the deviation of the calculated calibration parameters was $1.631 \times 10^{-4} \mathrm{~mm}$.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/isstc63573.2024.10824051
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Algorithms for Calibration of Laser Scanning Projection System

Fang Tang, Maosheng Hou, Kang Jian-guo, Yuhao Wang et al.
Advanced Measurement and Detection Methods
article

Research on Algorithms for Calibration of Laser Scanning Projection System

Fang Tang, Maosheng Hou, Kang Jian-guo, Yuhao Wang, Wu Kun, Guo Maoning
article en

Abstract

The calibration process of laser scanning projection system requires accurate positioning of cooperative targets and precise calculation of coordinate transformation equations. Therefore, this study analyzed the main causes of projection distortion in laser scanning projectors based on a dual-axis galvanometer, established a corresponding mathematical model, optimized the coordinate transformation equation used for calibration, and studied the use of an adaptive weight particle swarm optimization algorithm for its calculation. Meanwhile, the study also explored the Otsu-optimized Canny operator and combined it with the Delaunay triangulation algorithm to process the scanning detection data of cooperative targets and quickly extract their center coordinates. The comprehensive application of these algorithms was experimentally validated using actual measurement data, and the results indicated that the deviation of the calculated calibration parameters was $1.631 \times 10^{-4} \mathrm{~mm}$.

Changchun University of Science and Technology (CN), Chinese People’s Liberation Army 263 hospital (CN), Beijing Information Science & Technology University (CN)
Openalex Percentile: Top 77%
Advanced Measurement and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.