The Theoretical Description for the Use of Poly(7-hydroxyphenoxazone) as Electrode Modifier for pH Monitoring

The possibility of electroanalytical variation for a well-known litmus acidity test has been evaluated theoretically. In this system, pH is measured by a carbon material electrode, modified by the electropolymerized 7-hydroxyphenoxazone – the most pH-sensitive litmus dye. The investigation of the correspondent mathematical modeling confirms that the poly(7-hydroxyphenoxazone)-modified cathode is suitable for the pH measurements, especially in neutral and acidic solutions. Although the oscillatory and monotonic instabilities are more probable than in similar systems, the electroanalytical process tends to be efficient, and the analytical signal is easy to interpret.

Publication Details

Journal
Biointerface Research in Applied Chemistry
Published
2024-10-15
DOI
https://doi.org/10.33263/briac145.111
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Theoretical Description for the Use of Poly(7-hydroxyphenoxazone) as Electrode Modifier for pH Monitoring

Biointerface Research in Applied Chemistry
Analytical Chemistry and Sensors
article

The Theoretical Description for the Use of Poly(7-hydroxyphenoxazone) as Electrode Modifier for pH Monitoring

article en

Abstract

The possibility of electroanalytical variation for a well-known litmus acidity test has been evaluated theoretically. In this system, pH is measured by a carbon material electrode, modified by the electropolymerized 7-hydroxyphenoxazone – the most pH-sensitive litmus dye. The investigation of the correspondent mathematical modeling confirms that the poly(7-hydroxyphenoxazone)-modified cathode is suitable for the pH measurements, especially in neutral and acidic solutions. Although the oscillatory and monotonic instabilities are more probable than in similar systems, the electroanalytical process tends to be efficient, and the analytical signal is easy to interpret.

Biointerface Research in Applied ChemistryVol. 14(5)
Universidade do Porto, Universidade de Trás-os-Montes e Alto Douro
Clean water and sanitation
Openalex Percentile: Top 73%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.