Portable Decontamination System based on Cold Atmospheric Plasma and UV-C Light

This paper presents the design and testing of a portable decontamination system based on cold atmospheric plasma and UV-C light that could serve to decontaminate medical devices in remote areas or during epidemiological crises and natural disasters, as well as other items whose material composition makes them unsuitable for traditional decontamination methods used in hospitals. The efficacy of the prototype was verified through biological testing using bacteria Escherichia coli and Bacillus subtilis, as well as microorganisms commonly found in people’s hands. Results show that with a short exposure time of 5 minutes there was a log reduction of 1.91 for Escherichia coli and larger than 6 for Bacillus subtilis, meaning a disinfectant effectiveness of $98.8 \%$ and $100 \%$, respectively. Furthermore, two DBD reactors were used in asynchronous operation-mode to reduce energy consumption without sacrificing the species generated and the ionic wind produced.

Authors

Institutions

Publication Details

Published
2024-10-23
DOI
https://doi.org/10.1109/iestec62784.2024.10820303
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable Decontamination System based on Cold Atmospheric Plasma and UV-C Light

Zeuz Capitan‐Barrios, Dorindo Cárdenas, Sherlie Portugal
Fire Detection and Safety Systems
article

Portable Decontamination System based on Cold Atmospheric Plasma and UV-C Light

Zeuz Capitan‐Barrios, Dorindo Cárdenas, Sherlie Portugal
article en

Abstract

This paper presents the design and testing of a portable decontamination system based on cold atmospheric plasma and UV-C light that could serve to decontaminate medical devices in remote areas or during epidemiological crises and natural disasters, as well as other items whose material composition makes them unsuitable for traditional decontamination methods used in hospitals. The efficacy of the prototype was verified through biological testing using bacteria Escherichia coli and Bacillus subtilis, as well as microorganisms commonly found in people’s hands. Results show that with a short exposure time of 5 minutes there was a log reduction of 1.91 for Escherichia coli and larger than 6 for Bacillus subtilis, meaning a disinfectant effectiveness of $98.8 \%$ and $100 \%$, respectively. Furthermore, two DBD reactors were used in asynchronous operation-mode to reduce energy consumption without sacrificing the species generated and the ionic wind produced.

Universidad de Panamá (PA), Universidad Tecnológica de Panamá (PA)
Openalex Percentile: Top 69%
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.