Evaluation Method of Contact Erosion Degree of Reactive Power Switching Circuit Breaker

Reactive power switches break special types of loads and are frequently operated. Accurately mastering their arc extinguishing performance is of great significance for the rational formulation of maintenance plans and the effective prevention of breaking failures, circuit breaker explosions and other serious accidents. The degree of erosion of the arc contact is the most important factor affecting its arc extinguishing performance. In this study, we crafted arc contact models exhibiting varying levels of erosion, specifically five distinct stages, within a laboratory setting. We then conducted simulations to observe the breaking process across a range of capacitive load scenarios. Concurrently, we captured and quantified the electromagnetic wave signals emitted throughout these breaking events before proceeding to analyze the collected data. Our findings indicate a pronounced correlation: as the severity of arc contact erosion escalates, there is a significant rise in both the quantity and intensity of the emitted electromagnetic waves. This approach offers a viable method for assessing the erosion level of arc contacts in reactive power switches when subjected to energized conditions.

Authors

Institutions

Publication Details

Published
2024-11-28
DOI
https://doi.org/10.1109/icaica63239.2024.10823074
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation Method of Contact Erosion Degree of Reactive Power Switching Circuit Breaker

Bo Yu, Jianzhong Sun, Guoguang Du, Jie Yang et al.
Electrical Contact Performance and Analysis
article

Evaluation Method of Contact Erosion Degree of Reactive Power Switching Circuit Breaker

Bo Yu, Jianzhong Sun, Guoguang Du, Jie Yang, Xing Tong, Xiaobing Zhao
article en

Abstract

Reactive power switches break special types of loads and are frequently operated. Accurately mastering their arc extinguishing performance is of great significance for the rational formulation of maintenance plans and the effective prevention of breaking failures, circuit breaker explosions and other serious accidents. The degree of erosion of the arc contact is the most important factor affecting its arc extinguishing performance. In this study, we crafted arc contact models exhibiting varying levels of erosion, specifically five distinct stages, within a laboratory setting. We then conducted simulations to observe the breaking process across a range of capacitive load scenarios. Concurrently, we captured and quantified the electromagnetic wave signals emitted throughout these breaking events before proceeding to analyze the collected data. Our findings indicate a pronounced correlation: as the severity of arc contact erosion escalates, there is a significant rise in both the quantity and intensity of the emitted electromagnetic waves. This approach offers a viable method for assessing the erosion level of arc contacts in reactive power switches when subjected to energized conditions.

Jilin Electric Power Research Institute (China) (CN)
Climate action
Openalex Percentile: Top 74%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.