PHITS Simulation Analysis of the Performance of Pediatric Thyroid Screening Measurements Using NaI(Tl) Spectrometer

Background: A NaI(Tl) survey meter was used in the pediatric thyroid screening conducted after the Fukushima Daiichi Nuclear Power Plant accident. However, this measurement method has the weakness that it is difficult to selectively identify 131I. In this study, we analyzed the performance of an energy-analyzable NaI(Tl) spectrometer using the Particle and Heavy Ion Transport code System (PHITS), which allows Monte Carlo simulation of radiation transport.Materials and Methods: The spectrum of energy emitted by the NaI(Tl) spectrometer was simulated for a total energy absorption peak by adjusting factors that affect pulse wave height. From these simulation results, the detection limits of the NaI(Tl) spectrometer were obtained using Monte Carlo simulation.Results and Discussion: The energy spectrum results were reproduced with an accuracy of 0.1% to 44.0% for total energy absorption peaks. The calculated detection limit for 131I activity equivalent to 100 mSv in the thyroid under a 0.2 μSv· hr−1 ambient dose rate was approximately 80–90 Bq, which could be detected for up to 38 days after 131I intake in a 1-year-old child.Conclusion: This study demonstrated that pediatric thyroid screening using an NaI(Tl) spectrometer can practically provide greater accuracy than NaI(Tl) survey meters.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Protection and Research
Published
2024-12-30
DOI
https://doi.org/10.14407/jrpr.2024.00157
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PHITS Simulation Analysis of the Performance of Pediatric Thyroid Screening Measurements Using NaI(Tl) Spectrometer

Michiaki Kai, Takahiro Kitajima, Yoshimitsu Shinagawa, Mitsuaki Ojima
Journal of Radiation Protection and Research
Radioactive contamination and transfer
article

PHITS Simulation Analysis of the Performance of Pediatric Thyroid Screening Measurements Using NaI(Tl) Spectrometer

Michiaki Kai, Takahiro Kitajima, Yoshimitsu Shinagawa, Mitsuaki Ojima
article en

Abstract

Background: A NaI(Tl) survey meter was used in the pediatric thyroid screening conducted after the Fukushima Daiichi Nuclear Power Plant accident. However, this measurement method has the weakness that it is difficult to selectively identify 131I. In this study, we analyzed the performance of an energy-analyzable NaI(Tl) spectrometer using the Particle and Heavy Ion Transport code System (PHITS), which allows Monte Carlo simulation of radiation transport.Materials and Methods: The spectrum of energy emitted by the NaI(Tl) spectrometer was simulated for a total energy absorption peak by adjusting factors that affect pulse wave height. From these simulation results, the detection limits of the NaI(Tl) spectrometer were obtained using Monte Carlo simulation.Results and Discussion: The energy spectrum results were reproduced with an accuracy of 0.1% to 44.0% for total energy absorption peaks. The calculated detection limit for 131I activity equivalent to 100 mSv in the thyroid under a 0.2 μSv· hr−1 ambient dose rate was approximately 80–90 Bq, which could be detected for up to 38 days after 131I intake in a 1-year-old child.Conclusion: This study demonstrated that pediatric thyroid screening using an NaI(Tl) spectrometer can practically provide greater accuracy than NaI(Tl) survey meters.

Journal of Radiation Protection and ResearchVol. 49(4)
Nippon Bunri University (JP), Oita University of Nursing and Health Sciences (JP)
Affordable and clean energy
Openalex Percentile: Top 78%
Radioactive contamination and transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PHITS Simulation Analysis of the Performance of Pediatric Thyroid Screening Measurements Using NaI(Tl) Spectrometer — Michiaki Kai, Takahiro Kitajima, et al. · Journal of Radiation Protection and Research (2024) | TGRS Research Map | TGRS