Design and Validation of Mechanomyography and Torque Measurement Acquisition System for Skeletal Muscle Function

Assessment of muscle function is crucial for mitigating the risks of progressive motor weakness, which can ultimately lead to complete muscle impairment. However, existing technologies using commercial dynamometers are expensive, lack open-source availability and are not portable, limiting their accessibility in research settings. This study presents a cost-effective device to record muscle activity and the corresponding elbow joint torque. The device comprises three primary components:1) transducers for Mechanomyography (MMG), 2) torque signals detection, and 3) an application peripheral interface (API) for data acquisition control, visualization, and recording. Both transducers are integrated into an ATMEL ATMEGA 328. The device was validated on 36 able-bodied participants, measuring their MMG and torque across two sessions. Neuromuscular Electrical Stimulation (NMES) was applied to the Biceps Brachii (BB) muscle to induce elbow flexion. Further, submaximal torque and MMG were obtained using a commercial dynamometer and acceleration sensors for comparison. MMG measurements were observed at a maximum mean power frequency beyond 25Hz, while the torque information was found at 10 - 15 % of the Maximum Isometric Contraction (MVIC) induced by NMES. The measurement reliability was assessed using an Interclass Correlation Coefficient (ICC2,1) for elbow joint flexion torque (TQ RMS) and MMG RMS, yielding values between 0.522 and 0. 828. The ICC for the torque measurement device was 0.839, with SEM varying from 3.963 Nm to 11.149 Nm at a CV % of 2.565 to 13.123. These results underscore the potential of the developed device as a reliable, cost-effective alternative, with the added benefit of being replicable using locally available, low-cost electronics.

Authors

Publication Details

Journal
International Journal of Electrical and Electronics Engineering
Published
2024-12-31
DOI
https://doi.org/10.14445/23488379/ijeee-v11i12p125
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Validation of Mechanomyography and Torque Measurement Acquisition System for Skeletal Muscle Function

Raphael Uwamahoro, Farah Shahnaz Feroz, Kenneth Sundaraj
International Journal of Electrical and Electronics Engineering
Muscle activation and electromyography studies
article

Design and Validation of Mechanomyography and Torque Measurement Acquisition System for Skeletal Muscle Function

Raphael Uwamahoro, Farah Shahnaz Feroz, Kenneth Sundaraj
article en

Abstract

Assessment of muscle function is crucial for mitigating the risks of progressive motor weakness, which can ultimately lead to complete muscle impairment. However, existing technologies using commercial dynamometers are expensive, lack open-source availability and are not portable, limiting their accessibility in research settings. This study presents a cost-effective device to record muscle activity and the corresponding elbow joint torque. The device comprises three primary components:1) transducers for Mechanomyography (MMG), 2) torque signals detection, and 3) an application peripheral interface (API) for data acquisition control, visualization, and recording. Both transducers are integrated into an ATMEL ATMEGA 328. The device was validated on 36 able-bodied participants, measuring their MMG and torque across two sessions. Neuromuscular Electrical Stimulation (NMES) was applied to the Biceps Brachii (BB) muscle to induce elbow flexion. Further, submaximal torque and MMG were obtained using a commercial dynamometer and acceleration sensors for comparison. MMG measurements were observed at a maximum mean power frequency beyond 25Hz, while the torque information was found at 10 - 15 % of the Maximum Isometric Contraction (MVIC) induced by NMES. The measurement reliability was assessed using an Interclass Correlation Coefficient (ICC2,1) for elbow joint flexion torque (TQ RMS) and MMG RMS, yielding values between 0.522 and 0. 828. The ICC for the torque measurement device was 0.839, with SEM varying from 3.963 Nm to 11.149 Nm at a CV % of 2.565 to 13.123. These results underscore the potential of the developed device as a reliable, cost-effective alternative, with the added benefit of being replicable using locally available, low-cost electronics.

International Journal of Electrical and Electronics EngineeringVol. 11(12)
University of Rwanda, Universiti Teknikal Malaysia Melaka
Openalex Percentile: Top 77%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Validation of Mechanomyography and Torque Measurement Acquisition System for Skeletal Muscle Function — Raphael Uwamahoro, Farah Shahnaz Feroz, et al. · International Journal of Electrical and Electronics Engineering (2024) | TGRS Research Map | TGRS